mobile-main-menu-button
Menu

WaveDriver 40 Spectroelectrochemistry Bundle

Products

To view pricing, you must create an account and login using the "ACCOUNT" menu above.

Purchase of a Pine Research Potentiostat includes a free 1-hour online training session!  Contact Pine Research now (click here) to learn more and to schedule your training session.

This instrument bundle includes our WaveDriver 40 DC bipotentiostat, a UV/Visible spectrometer system, and our Honeycomb Spectroelectrochemical Cell kit. The system offers a fast and easy approach to acquiring spectroelectrochemical research results. This complete system includes the following principle components:

  • WaveDriver 40 DC Bipotentiostat/Galvanostat System
  • Honeycomb Spectroelectrochemical Cell Kit
  • AvaSpec-UL S2048 UV/Vis Spectrometer (CCD array, 2048 pixels, 200 - 1100 nm range)
  • AvaLight UV/Vis/NIR Light Source (dual lamp light source, deuterium and halogen, provides light between 200 and 2500 nm at a convenient front panel SMA connector)

To view pricing, you must create an account and login using the "ACCOUNT" menu above.

# Description Price in USD
Spectroelectrochemistry Bundle
[WD40-SPEC]

WaveDriver 40 Spectroelectrochemistry Bundle
includes WaveDriver 40, Avantes spectrometer, and Honeycomb spectroelectrochemical cell

Bundle includes the items listed below
AFP4

WaveDriver 40 DC Bipotentiostat/Galvanostat
includes power adapter, USB cable, and dummy cell

Software

click here for AfterMath software information

ACP3E01

WaveDriver 40 Cell Cable Kit
7-lead, includes alligator clips

RRAVSP3

AvaSpex-UL S2048 Fiber-Optic Spectrometer
2048 pixel CCD array, 200-1100 nm range

USB powered

RRAVCH

Fiber Optic Cuvette Holder 
SMA connector for incident and emited light through cuvette. Cuvette holder is compatible with Honeycomb Cell Kit Cuvette

RRAVSP

AvaLight UV/Vis/NIR Light Source
Dual lamp light source, deuterium and halogen, provides light between 200 and 2500 nm at a convenient front panel SMA connector

Power supply sold separately

RRAVPC

AC Power Supply 
Used for light source

UV/Vis Spectrometer is USB powered

RRAVFC2

Fiber-Optic Cables
Includes two 600 nm cables, suitable for UV/Vis/NIR 250 to 2500 nm.  Each cable is 2 m long with SMA-905 connector

RRAVCB-T

Integration Cable
Connects WaveDriver 40, UV/Vis spectrometer, and light source together

ACP2E09

WaveDriver mini-USB cell cable with reference electrode breakout
connects potentiostat to spectroelectrochemical cell

AKSTCKIT3

Spectroelectrochemical Cell Kit
includes cuvette with cap, one Pt honeycomb electrode, two Au honeycomb electrodes, and gel-based Ag/AgCl reference electrode

RREF0153L2

Low-Profile Silver-Wire Pseudo-Reference electrode
60 mm long reference electrode, PTFE capped Ag wire electrode (19 mm long wire), 3.4 mm OD ceramic-fritted glass tube (52 mm long), and O-ring

WaveDriver 40 Power Cord
Power Cords

click here to review power cord options

this bundle requires a power cord

All specifications are subject to change without notice.
WaveDriver 40 DC Bipotentiostat

Working Electrode Channels

2

Measured Current Ranges

±1 A, ±100 mA, ±10 mA, ±1 mA, ±100 μA, ±10 μA, ±1 μA, ±100 nA

Autoranging

Yes

Practical Current Range

5 pA to 1.0 A

ADC Input

16 bits

Compliance Voltage

> ±17 V

Measured Potential Ranges

±15.0 V, ±10.0 V, ±2.5 V

CV Sweep Rate (min)

10 μV/s (469 μV per 46.9 s, 313 μV step per 31.3 s or 78 μV per 7.8 s)

CV Sweep Rate (max)

75 V/s

Point Interval

80 μs (minimum)

EIS Capable

No

EIS Frequency Range

N/A

Instrument Dimensions

160 × 324 × 255 mm
(6.3 × 12.75 × 10.0 in)

Instrument Weight

4.6 kg (10.2 lb)

Additional Specifications

click here for a complete list of specifications

Document # Title
WaveDriver 40 DC Bipotentiostat/Galvanostat

DRU10165

WaveDriver 40 User Guide
click here to download (6 MB download)

Integrated Spectroelectrochemical System

DRP10208

Spectroelectrochemical Cell User Guide
click here to download (2 MB download)

DRB10074

Spectroelectrochemistry Brochure
click here to download (1 MB download)

Contact us with any questions or support requests by phone or e-mail.

Below are selected product references:

WaveDriver 40 DC Bipotentiostat [AFP4]
AvaSpec-UL S2048 Fiber-optic Spectrometer [RRAVSP3]
AvaLight UV/Vis/NIR Light Source [RRAVSP]
Honeycomb Spectroelectrochemical Cell Kit [AKSTCKIT3]
Questions? Find Answers.

Our knowledgebase is the central repository for written content, including help topics, theory, application notes, specifications, and software information.

Select a category below or view the Knowledgebase home page
Software

Detailed information about our Software, which includes AfterMath and retired PineChem.

Applications

Application notes discuss practical aspects of conducting specific experiments.

Theory

Fundamental electrochemical theory presented in a brief and targeted manner.

Product Specifications

Review complete product specifications and compare products within a category here.