Pine Research Instrumentation logo

Reference Electrode Storage Vessel

Part Number
RRPG209

This storage vessel is designed to be filled with an appropriate electrolyte solution (total volume = 500 mL) which keeps the reference electrode junction (frit) wetted when not in use.  The vessel has four side ports (14/20), each of which may be used to vertically orient and mount a standard size reference electrode (9.5 mm OD).  The center port (14/20) may be used to mount a “laboratory master” reference electrode, which is typically kept separate and not used in any electrochemical experiments.  This “master” reference electrode functions as a constant potential with which to check the accuracy of remaining reference electrodes of the same type.  Two larger ports (24/25) facilitate periodic draining and refilling the vessel.

Login to View Prices

Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.

This storage vessel is designed to be filled with an appropriate electrolyte solution (total volume = 500 mL) which keeps the reference electrode junction (frit) wetted when not in use.  The vessel has four side ports (14/20), each of which may be used to vertically orient and mount a standard size reference electrode (9.5 mm OD).  The center port (14/20) may be used to mount a “laboratory master” reference electrode, which is typically kept separate and not used in any electrochemical experiments.  This “master” reference electrode functions as a constant potential with which to check the accuracy of remaining reference electrodes of the same type.  Two larger ports (24/25) facilitate periodic draining and refilling the vessel.

More Detail
This storage vessel is designed to be filled with an appropriate electrolyte solution (total volume = 500 mL) which keeps the reference electrode junction (frit) wetted when not in use.  The vessel has four side ports (14/20), each of which may be used to vertically orient and mount a standard size reference electrode (9.5 mm OD).  The center port (14/20) may be used to mount a "laboratory master" reference electrode, which is typically kept separate and not used in any electrochemical experiments.  This "master" reference electrode functions as a constant potential with which to check the accuracy of remaining reference electrodes of the same type.  Two larger ports (24/25) facilitate periodic draining and refilling the vessel.