Join the rest of the community that depends on Pine Research Instrumentation Rotating Cylinder Electrode systems.   Our 15 mm RCE electrode system is the trusted tool to perform corrosion analysis, namely screening of corrosion inhibitors.  Identifying and selecting all the required components of a complete RCE electrochemical corrosion screening system can be a daunting task.  We have helped ease that burden by organizing RCE bundle options with several options to suit your laboratory needs.

The RCE Bundle with Cell with Drain Valve is everything you need except an Electrochemical Workstation and MSR evo Electrode Rotator and features the 1 liter cell with drain valve.

Product Bundle

This is a product bundle, meaning several compatible products are included together. View the individual bundle products in the tab below.

Login to View Prices

Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.

Join the rest of the community that depends on Pine Research Instrumentation Rotating Cylinder Electrode systems.   Our 15 mm RCE electrode system is the trusted tool to perform corrosion analysis, namely screening of corrosion inhibitors.  Identifying and selecting all the required components of a complete RCE electrochemical corrosion screening system can be a daunting task.  We have helped ease that burden by organizing RCE bundle options with several options to suit your laboratory needs.

The RCE Bundle with Cell with Drain Valve is everything you need except an Electrochemical Workstation and MSR evo Electrode Rotator and features the 1 liter cell with drain valve.

More Detail
Bundle Products
Specifications
Join the rest of the community that depends on Pine Research Instrumentation Rotating Cylinder Electrode systems.   Our 15 mm RCE electrode system is the trusted tool to perform corrosion analysis, namely screening of corrosion inhibitors.  Identifying and selecting all the required components of a complete RCE electrochemical corrosion screening system can be a daunting task.  We have helped ease that burden by organizing RCE bundle options with several options to suit your laboratory needs.  A complete RCE system requires a potentiostat, electrode rotator, rotating cylinder electrode, cell with all accessories, counter electrode, reference electrode, and common accessories such as Luggin tubes and gas sparge/purge tubes. The corrosion cell included with this bundle is the 1 liter basic cell with drain valve, perfect for controlling solution temperature on a hot plate.

The 15 mm OD Rotating Cylinder Electrode (RCE) system features a number of improvements over previous designs which will assist you in your high velocity (high shear) corrosion testing.   The larger 15 mm diameter gives you more wall shear at the cylinder surface at a given rotation rate (as compared to the traditional 12 mm OD design).

Insulation. All shaft components are fabricated from a chemically resistant polymer (PEEK) to protect the shaft from corrosive attack during testing. At elevated temperatures, this polymer has good mechanical stability as compared to the traditional PTFE-based 12 mm OD design. One Liter Cell. With an overall one liter capacity, the cell features a removable lid with six flexible side ports. You can equip your cell with a variety of accessories (condenser, pH measurement, thermowell, each sold separately) while still having enough ports for the reference and counter electrode. Cells with drain valves and water jackets are also available. Alignment. The standard RCE glass cell features a special recess in the bottom of the cell into which the lower end of the RCE shaft is inserted. This recess provides a guide for aligning the shaft along the center line of the cell. Purging. A dual port purge accessory is included with the cell which permits you to sparge the solution and/or blanket the solution with a purge gas. In addition, the gas-purged bearing assembly, through which the rotating shaft enters the cell, has a separate purge port so that you can maintain a positive purging pressure within the internal space of the bearing itself. Specimens. The lower end of the electrode shaft accepts 15 mm OD x 6.4 mm tall replaceable cylinder inserts. The nominal cylindrical surface area exposed to the solution is 3.0 square centimeters. Standard cylinder inserts fabricated from a variety of steel materials are offered by Pine Research. Custom inserts fabricated from other materials are available upon request. Alternately, cylinder inserts with the appropriate dimensions may be fabricated by the customer. Contact. Reliable electrical contact between the shaft and the replaceable cylinder insert is accomplished using a spring-loaded ball plunger which pushes against the inside diameter of the cylinder insert.
Corrosion Cell Kit Bundle, Complete OpenTop Cell Kit with Drain Valve, 15 mm RCE is sold as a product bundle. Product bundles combine multiple products into one purchase. For details or to purchase additional items, visit the product page for any item in the bundle below.
Qty
Image
Product Name
Part #
1
Rotating Cylinder Cell Kit, OpenTop, 15 mm OD RCE, Drain Valve
AFCELL8U
1
E9 Series Precision RCE Shaft 15 mm Cylinders
AFE9MBA
1
Bearing Assembly, Gas-Purged, for AFE6MB/AFE9MBA Shaft, PEEK, with 24/25 Taper
AC01TPA6M
1
Counter Electrode Assembly, Graphite (C), 24/25
AFCTR3
1
Luggin Tube for OpenTop RCE Cells
RRPG031
1
Dual Port Gas Inlet for 15 mm OD RCE Cells, 24/25 Taper
RRPG034
Corrosion Cell Kit Bundle, Complete OpenTop Cell Kit with Drain Valve, 15 mm RCE is sold as a product bundle. The data below aggregates the specifications for each product contained within the bundle..
Corrosion Cell Kit Bundle, Complete OpenTop Cell Kit with Drain Valve, 15 mm RCE
Product Bundles
Product bundle
Bundle application
Corrosion, Rotating Cylinder (RCE)
E9 Series Precision RCE Shaft 15 mm Cylinders
Working Electrodes
General
Electrode series
Thermal stability range
10°C - 80°C
Rotating Electrodes
Maximum rotation rate
Cylinder Electrodes
Cylinder series compatibility
AFE9C150 (15 mm OD)
Electrode Rotator
Compatibility
Compatible electrode tips
Applications
Rotating application
Electrode Shafts
Shaft length (overall)
259 mm (10.2 in)
Shaft shroud diameter
Shaft shroud length
152 mm
Shaft shroud material