Low Volume Cell Series Cap Kit

Part Number
AF01CKT1004

The Low Volume Cap Kit can be used in two configurations – either open or closed to the atmosphere. The cap kit has the option for sealing around all electrodes and probes in the cell with optimally-sized fluoroelastomer O-rings and a sealing mechanical cap. Fluoroelastomer (FKM) O-rings are not chemically compatible in all solvent systems. FKM provides good coverage of many commonly used solvents. Customers using more aggressive solvents are encouraged to source their own O-rings to suit their application. This cap kit is included with each Low Volume Cell Kit. Replacements can be purchased as a kit. The cap is machined from chemically-resistant PEEK polymer.

Product Kit

This product is sold as a kit, meaning it consists of multiple independent products used together. View the individual kit products in the tab below.

Related Product Kits

This product is available in related kits. View related kits in the tab below.

Login to View Prices

Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.

The Low Volume Cap Kit can be used in two configurations – either open or closed to the atmosphere. The cap kit has the option for sealing around all electrodes and probes in the cell with optimally-sized fluoroelastomer O-rings and a sealing mechanical cap. Fluoroelastomer (FKM) O-rings are not chemically compatible in all solvent systems. FKM provides good coverage of many commonly used solvents. Customers using more aggressive solvents are encouraged to source their own O-rings to suit their application. This cap kit is included with each Low Volume Cell Kit. Replacements can be purchased as a kit. The cap is machined from chemically-resistant PEEK polymer.

More Detail
Kit Products
Related Kits
Specifications
References
Documents

The Low Volume Cap Kit can be used in two configurations - either open or closed to the atmosphere. The cap kit has the option for sealing around all electrodes and probes in the cell with optimally-sized fluoroelastomer O-rings and a sealing mechanical cap. Fluoroelastomer (FKM) O-rings are not chemically compatible in all solvent systems. FKM provides good coverage of many commonly used solvents. Customers using more aggressive solvents are encouraged to source their own O-rings to suit their application. This cap kit is included with each Low Volume Cell Kit. Replacements can be purchased as a kit. The cap is machined from chemically-resistant PEEK polymer.

Low Volume Cell Series Cap Kit is sold as a product kit. Product kits contain more than one product when purchased. Should you want more details on a specific part in the kit or wish to order an additional or replacement of a component, you can visit the product page for any item in the kit below.
Qty
Image
Product Name
Part #
1
Placeholder Image
Low Volume Cell Cap Component: Bottom Part with 24/25 Taper
AC01CKT1004M01
1
Placeholder Image
Low Volume Cell Cap Component: Top Part (Seal Cap)
AC01CKT1004M02
4
Placeholder Image
Low Volume Cell Cap Component: 6.4 mm OD Plug
AC01CKT1004M03
1
Placeholder Image
Low Volume Cell Cap Component: 3.5 mm OD Plug
AC01CKT1004M04
2
O-Ring, Viton, Round, 3 mm OD
KAA030VM
8
O-Ring, Viton, Round, 6 mm OD
KAA060VM
8
O-Ring, Viton, Round, 7 mm OD
KAA070VM
2
O-Ring, Viton, Round, 20 mm OD
KAA200VM
3
Placeholder Image
Low Volume Cell Cap Component: Cap Screw (Screw Only)
KSM0440P08PS
The Low Volume Cell Series Cap Kit is included in one or more kits. Below is a list of kits that contain this product.
Image
Kit Name
Kit Part #
Advanced Luggin Low Volume Membrane Cell Kit
AFCKT1031
Three Electrode Cell Kit, Low Volume, Alkaline Resistant
AF01CKT1003
H-Cell Kit, Low Volume
AF01CKT1007
Separated Cell Kit, Low Volume
AF01CKT1008
Three Electrode Cell Kit, Low Volume, Alkaline Resistant, Gold (Au) Working Electrode
[LVC3-AUE]
Three Electrode Cell Kit, Low Volume, Alkaline Resistant, Glassy Carbon (GC) Working Electrode
[LVC3-GCE]
Three Electrode Cell Kit, Low Volume, Alkaline Resistant, Platinum (Pt) Working Electrode
[LVC3-PTE]
Low Volume Cell Kit, Au Working Electrode
[LVC6-AUE]
Low Volume Cell Kit, GC Working Electrode
[LVC6-GCE]
Low Volume Cell Kit, Pt Working Electrode
[LVC6-PTE]
Low Volume Cell Kit, Utili-Shaft Style A
[LVC7-A1]
Low Volume Cell Kit, Utili-Shaft Style B
[LVC7-B1]
Low Volume Cell Series Cap Kit is sold as a product kit. The data below aggregates the specifications for each product contained within the kit..
Low Volume Cell Series Cap Kit
Product Kits
Product kit
Kit includes
Cell cap, Cell cap kit, O-rings, Plugs, Screws
O-Ring, Viton, Round, 3 mm OD
O-Ring Dimensions
O-ring material
O-ring cross section shape
Round
O-ring outer diamter (OD)
5 mm
O-ring inner diamter (ID)
3 mm
O-ring width (W)
1 mm
O-Ring, Viton, Round, 6 mm OD
O-Ring Dimensions
O-ring material
O-ring cross section shape
Round
O-ring outer diamter (OD)
8 mm
O-ring inner diamter (ID)
6 mm
O-ring width (W)
1 mm
O-Ring, Viton, Round, 7 mm OD
O-Ring Dimensions
O-ring material
O-ring cross section shape
Round
O-ring outer diamter (OD)
9 mm
O-ring inner diamter (ID)
7 mm
O-ring width (W)
1 mm
O-Ring, Viton, Round, 20 mm OD
O-Ring Dimensions
O-ring material
O-ring cross section shape
Round
O-ring outer diamter (OD)
22 mm
O-ring inner diamter (ID)
20 mm
O-ring width (W)
1 mm
When possible, we add published articles, theses and dissertations, and books to our references library. When we know this product has been used, we will include it in this list below. If you have a reference where our product was used and it's not in this list, please contact us with the details and we will add it.
  1. Bard et al. Electrochemical Methods: Fundamentals and Applications, 3rd ed; John Wiley & Sons, Ltd: Hoboken, NJ, 2022.
  2. Orazem and Tribollet Electrochemical impedance spectroscopy, 2nd ed; John Wiley & Sons, Inc.: Hoboken, NJ, 2017.
  3. Leddy, J., Paschkewitz, T. Ammonia production using bioelectrocatalytical devices. US9506085B2, 2016.
  4. Esrafilzadeh et al. Room temperature CO2 reduction to solid carbon species on liquid metals featuring atomically thin ceria interfaces. Nature Communications, 2019, 10, 865.
  5. Ashok et al. Single Step Synthesis of Porous NiCoO2 for Effective Electrooxidation of Glycerol in Alkaline Medium. Journal of The Electrochemical Society, 2018, 165, J3301-J3309.
  6. Yang and Venton. Carbon Nanomaterials for Neuroanalytical Chemistry. In Nanocarbons for Electroanalysis; Szunerits, S., Boukherroub, R., Downard, A., Zhu, J. Eds; John Wiley & Sons, Ltd: Chichester, UK, 2017-09; pp 55-83.
  7. Baker et al. Organophosphate vapor detection on gold electrodes using peptide nanotubes. Biosensors and Bioelectronics, 2014, 61, 119–123.
  8. Paschkewitz, Timothy. Ammonia Production at Ambient Temperature and Pressure. Ph.D. Dissertation, University of Iowa (Iowa City, Iowa), 2012-01.
Document #
Title
Type
Download
DRP10248
Use and Assembly of the Low Volume Cap Kit