This WaveDriver® 200 Electrochemical Workstation is a versatile, dual-electrode, research-grade, performance-driven system with potentiostat, galvanostat, EIS, open-circuit potential, and zero resistance ammeter modes of operation.   It is engineered to provide the essential hardware and software features you need at an affordable price.  This system finds use with stationary electrodes, rotating disk (RDE), rotating ring-disk (RRDE), and rotating cylinder (RCE) electrodes.

Under the control of our powerful AfterMath® Blue software package, the WaveDriver 200 supports a wide range of DC electroanalytical techniques as well as AC techniques like Electrochemical Impedance Spectroscopy (EIS). It offers current ranges up to ±1 A, potential ranges up to ±15 V, advanced inputs/outputs, waveform filters, EIS up to 1 MHz, and iR compensation.

The WaveDriver 200 is a true integrated bipotentiostat, capable of controlling one or two working electrodes operating in the same electrochemical cell along with a counter and reference electrode, making this instrument ideal for Rotating Ring-Disk Electrode (RRDE) voltammetry. This workstation is a trusted companion to our popular electrode rotators, including our latest evoLUTION, the MSR evo Electrode Rotator.

Product Bundle

This is a product bundle, meaning several compatible products are included together. View the individual bundle products in the tab below.

Product Parts List

This product consists of separately available parts. View the parts list in the tab below.

Login to View Prices

Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.

This WaveDriver® 200 Electrochemical Workstation is a versatile, dual-electrode, research-grade, performance-driven system with potentiostat, galvanostat, EIS, open-circuit potential, and zero resistance ammeter modes of operation.   It is engineered to provide the essential hardware and software features you need at an affordable price.  This system finds use with stationary electrodes, rotating disk (RDE), rotating ring-disk (RRDE), and rotating cylinder (RCE) electrodes.

Under the control of our powerful AfterMath® Blue software package, the WaveDriver 200 supports a wide range of DC electroanalytical techniques as well as AC techniques like Electrochemical Impedance Spectroscopy (EIS). It offers current ranges up to ±1 A, potential ranges up to ±15 V, advanced inputs/outputs, waveform filters, EIS up to 1 MHz, and iR compensation.

The WaveDriver 200 is a true integrated bipotentiostat, capable of controlling one or two working electrodes operating in the same electrochemical cell along with a counter and reference electrode, making this instrument ideal for Rotating Ring-Disk Electrode (RRDE) voltammetry. This workstation is a trusted companion to our popular electrode rotators, including our latest evoLUTION, the MSR evo Electrode Rotator.

Important
More Detail
Bundle Products
Specifications
Parts
Documents
Includes Free Training Session!

Every purchase of a WaveDriver electrochemical workstation includes a free one-hour online training session! Contact Pine Research to inquire about this free session.

Tip: Product Similarity

The WaveDriver 100 is a single channel electrochemical workstation with EIS, whereas the WaveDriver 200 is a two-channel bipotentiostat electrochemical workstation with EIS. The WaveDriver 40 does not have EIS, and is a two-channel bipotentiostat. Other specifications are shared among all current models of the WaveDriver Series.

Specify Power Cord

This product requires a power cord to connect to AC mains. Please specify the plug style used in your region when you order this product. We stock a variety of power cords.

WaveDriver 200 Electrochemical Workstation

The WaveDriver 200 Electrochemical Workstation is an excellent choice. Unlike other "bipotentiostats" on the market, this workstation electronics features a truly integrated bipotentiostat. You do not have to mess around with cell cables in obscure configurations to operate the workstation as a bipotentiostat. It is ready to use out of the box - just connect your clearly-marked cell cable leads to the desired electrodes and you are ready to go with your experiment, like rotating ring-disk (RRDE). No additional cables, adapters, or connectors required.

The WaveDriver 200 Electrochemical Workstation is engineered to provide the essential hardware and software features you need at an affordable price. It supports a wide range of DC electroanalytical techniques as well as AC techniques such as Electrochemical Impedance Spectroscopy (EIS). It offers current ranges up to ±1 A, potential ranges up to ±15 V, advanced inputs/outputs, waveform filters, EIS up to 1 MHz, and iR compensation. The WaveDriver 200 is a high performance, EIS-capable workstation with integrated bipotentiostat, which is ideal for use with stationary electrodes, RDE, RRDE, and RCE.

AfterMath Blue - Data Acquisition, Analysis, and Organization Software

Licenses for our AfterMath® Blue software are included with the purchase of an Electrochemical Workstation. The licenses give you access to all of the AC and DC methods that the WaveDriver 200 can perform. Pine Research does not charge extra for various categories of electrochemical techniques. If the instrument is capable of a method, you have access to it (no hidden costs). Here are some unique features of AfterMath Blue:

  • Instrument Control. When started, AfterMath automatically detects all compatible instrumentation attached to the computer and provides complete control over each instrument. It can simultaneously control multiple instruments and queue multiple experiments.
  • Flexible Plotting. AfterMath offers a powerful "drag-n-drop" feature for quickly copying and moving traces between plots, with precise control over various plot settings.
  • Scientific Units. Designed with scientific data in mind, AfterMath properly handles units, metric prefixes, and significant figures.
  • Data Archiving. A unique XML-based file format allows multiple related experiments to be stored in a single archive file, simplifying file management.
  • Tools and Transforms. Flexible tools allow precise measurement of quantities like peak height and area, with fundamental mathematical operations available on any trace.

Our talented team of engineers and chemists have taken a careful approach at integrating EIS into our Electrochemical Workstations. Our software engineering team has incorporated EIS equivalent circuit fitting directly into our AfterMath Blue software (no separate software required). Multiple curve fitting algorithms and options allow you to fit even the most troublesome data. Here are some of the exciting and novel EIS analysis features in AfterMath Blue:

  • Integrated Curve Fitting and Analysis. Our software team has seamlessly integrated EIS curve fitting into AfterMath. Why work with more than one software application to fit your EIS data when you can do it using the very same software application that acquired the data? AfterMath EIS curve fitting utilities provide several analyses, including Circuit Fit, Transmission Line, and Kramers-Kronig. Unlike others, our fitting software also provides several fitting methods including Modified Levenberg-Marquardt (LM), Simplex, and Powell algorithms in addition to fitting options that include dynamic point selection, unity, and parametric fitting.
  • Novel Transmission Line Fitting. AfterMath provides a unique approach to model your porous electrodes. While the transmission line model is not new, AfterMath provides you with some unique transmission line fitting tools. Instead of a static circuit, where you have no control over the elements of the model, we provide a very flexible basic model, from which you can customize nearly all aspects of the model to suit your system. Give it a try - import your three- or five-column EIS data directly into AfterMath and see the difference with our transmission line fitting.
  • Finishing Touches. While fitting your EIS data, why flip back and forth between Nyquist and Bode plots? Why not be able to view both plots and fits simultaneously? We heard this feedback from many customers and have designed AfterMath to provide you with both plots simultaneously during fitting. You can also draw your own equivalent circuits to fit your particular system.
WaveDriver 200 System Bundle is sold as a product bundle. Product bundles combine multiple products into one purchase. For details or to purchase additional items, visit the product page for any item in the bundle below.
Qty
Image
Product Name
Part #
1
WaveDriver 200 Bipotentiostat/Galvanostat with EIS Electrochemical Impedance Spectroscopy
WaveDriver 200 Electrochemical Workstation
AFP3
1
Power Cords
POWER-CORD
WaveDriver 200 System Bundle is sold as a product bundle. The data below aggregates the specifications for each product contained within the bundle.
WaveDriver 200 System Bundle
Product Bundles
Product bundle
Bundle application
Education, General electrochemistry, Photoelectrochemistry, Rotating Cylinder (RCE), Rotating Disk (RDE), Rotating Ring-Disk (RRDE), Spectroelectrochemistry
Bundled electrochemical workstation
WaveDriver 200 Electrochemical Workstation
Electrochemical Workstations
Electrode Connections
Reference electrode
Sense line with driven shield
Counter electrode
Drive line with grounded shield
Working electrode channels
Working electrode #1 (WK1)
Separate sense and drive lines, each with driven shield (current measurement via passive shunt)
Working electrode #2 (WK2)
Separate sense and drive lines, each with driven shield (current measurement via transimpedance amplifier). Note: AC techniques are not available on WK2.
Ground Connections
DC common (signal)
The DC Common is isolated from the USB port, the instrument chassis and earth ground. The DC Common is accessible via a banana binding post (black) on the back panel.
Chassis terminal
The instrument chassis terminal is accessible via a banana binding post (metal) on the back panel. The GRAY banana plug on the cell cable also provides a chassis connection.
Earth
No direct connection to earth ground is provided.
Measured Current (Potentiostatic Mode)
Current ranges (measured)
±1 A, ±1 mA, ±1 µA, ±10 mA, ±10 µA, ±100 mA, ±100 nA, ±100 µA
Current resolution at each range (measured)
3.13 nA, 3.13 pA, 3.13 µA, 31.3 nA, 31.3 pA, 31.3 µA, 313 nA, 313 pA
Autoranging
Yes
Practical current range
20 pA to 1 A
DC accuracy (current, measured)
±0.2% of setting; ±0.05% of range
DC leakage current
<10 pA at 25°C
AC accuracy (measured)
Frequency- and range-dependent to 1 MHz
AC leakage current
Frequency- and range-dependent to 1 MHz
ADC input
16 bits
Filters (for DC Experiments)
1 kHz, 10 Hz, 100 Hz, 100 kHz, 30 Hz
Applied Current (Galvanostatic Mode)
Current ranges (applied)
±1 A, ±1 mA, ±1 µA, ±10 mA, ±10 µA, ±100 mA, ±100 nA, ±100 µA
DC accuracy (current, applied)
±0.2% of setting; ±0.05% of range
Power Amplifier (Counter Electrode Amplifier)
Output current
±1 A (maximum)
Short circuit current limit
10 mA - 100 nA ranges: <200 mA, 1A, 100 mA ranges: <1.3 A
Compliance voltage
±17 V
Bandwidth
>2.5 MHz (on fastest speed setting)
Noise and ripple
<35 µV RMS in 2 MHz bandwidth
Slew rate/rise time
10 V/µs (on fastest speed setting)
Electrometer (Reference Electrode Amplifier)
Input impedance
>10¹² in parallel with <10 pF
Input current
<10 pA leakage/bias current at 25°C
CMRR
>100 dB, 0 - 1 kHz, >40 dB ≤ 1 MHz, >60 dB ≤100 kHz, >80 dB ≤10 kHz
Electrometer bandwidth
>15 MHz (3 dB)
Measured Potential
DC accuracy (potential, measured)
±0.2% of setting; ±0.05% of range
ADC output
16 bits
Filters (for DC Experiments)
1 kHz, 10 Hz, 100 Hz, 100 kHz, 30 Hz
Applied Potential (Potentiostatic Mode)
DC accuracy (potential, applied)
±0.2% of setting; ±0.05% of range
DAC output (potential)
16 bits
CV sweep rate (minimum)
10 µV/s
CV sweep rate (maximum)
75 V/s
Data Acquisition (for DC Experiments)
Clock resolution
10 ns (minimum time base)
Point interval
80 µs (minimum)
Synchronization
Simultaneous sampling of all analog input signals
Raw point total
<10 million per experiment
Electrochemical Impedance Spectroscopy (EIS)
EIS capable
EIS frequency range
10 µHz - 1 MHz
EIS frequency resolution
<1 ppm 1 MHz - 100 mHz, <70 ppm 1 mHz - 10 µHz, <80 ppm 100 mHz - 10 mHz, <90 ppm 10 mHz - 1 mHz
EIS frequency stability
±10 ppm
Modes
Galvanostatic, Potentiostatic
Voltage excitation setpoint
1 mV - 200 mV peak, ±10% of setting
Current excitation setpoint
0.01% - 100% of current range, 10% of setting, 200 mA maximum
Frequency sweeping
Custom list, Linear, Logarithmic
EIS accuracy
Rotator Control Connections
Rotator connector A
7-pin mini circular DIN includes analog and digital signal grounds, digital rotator enable signal (+15 V max), auxiliary digital output signal, and analog rotation rate control signal
Rotator connector B
3-pin connector includes analog signal ground, digital rotator enable signal (+15 V max), and analog rotation rate control signal
Rate control signal
±10 V, ±2.5 V
Digital enable signal
Open drain with 4.7 kΩ pull up to +5 V (TTL compatible)
Accessories
Dummy cell
External dummy cell included
Cell cable
Combination D-SUB connector to multiple banana plugs via shielded coaxial cables (included)
Auxiliary Connections
Connector C
9-pin DSUB connector that includes DC Common, two digital output signals, and two digital input signals
Trigger input
BNC female, TTL compatible
Trigger output
BNC female, TTL compatible
Potential (E1) output
BNC female, ±15 V, ±10 V, ±2.5 V output, ±0.5% accuracy
Current (I1) output
BNC female, ±10 V output, scaled to current range, ±0.5% accuracy
Potential (E2) output
BNC female, ±15 V, ±10 V, ±2.5 V output, ±0.5% accuracy
Current (I2) output
BNC female, ±10 V output, scaled to current range, ±0.5% accuracy
Auxiliary analog input
BNC female, ±10 V differential input, 313 µV resolution, 0.2% accuracy (available when second working electrode not in use)
Auxiliary analog output
BNC female, ±10 V bipolar output, 313 µV resolution, 0.2% accuracy (available when second working electrode not in use)
WK1 input
BNC female, ±10V differential input, 20 kΩ impedance, ±0.5% accuracy; allows external waveform to be summed directly to the working electrode excitation signal
WK2 input
BNC female, ±10V differential input, 20 kΩ impedance, ±0.5% accuracy; allows external waveform to be summed directly to the working electrode excitation signal
General
Power input
24 VDC (±5%), 5.0 A (low voltage DC device)
Power supply input
100 - 240 VAC, 1.4 - 0.7 A, 50 - 60 Hz
Power supply output
24 VDC, 5.0 A power supply (included) has a C14 type input connector
Power cord
Various international cables sold separately (C13 type)
LED indicators
Power, USB, and status
Instrument dimensions
160 × 324 × 255 mm (6.3 × 12.75 × 10.0 in)
Workstation shipping dimensions
254 × 356 × 457 mm (10 × 14 × 18 in)
Instrument weight
4.6 kg (10.2 lb)
Workstation shipping weight
7.7 kg (17 lb)
Temperature range
10°C - 40°C
Humidity range
80% RH maximum, non-condensing
Workstation modes
Galvanostat (GAL), Open-Circuit Potential (OCP), Potentiostat (POT), Zero-Resistance Ammeter (ZRA)
Communication
Interface
Wireless capable
Electrode Rotator
Safety & Environmental
Rotator RoHS compliant
Yes
Rotator safety certification
CE, ETL
Power Cords
WaveDriver 200 System Bundle is sold as a simple product; however, customers may wish to order replacement or additional components of this product. We call these "parts" of the product. Should you want more details on individual parts of this product or wish to order an additional or replacement part, refer to the list of parts below with links to their product page.
Qty
Image
Product Name
Part #
1
WaveDriver 200/WaveDriver 40 Electrochemical Workstation Cell Cable
ACP3E01
1
Universal Dummy Cell, Modular
AFDUM9
1
WaveDriver 40/100/200 Power Supply
RRPA24V5A
1
Power Cords
POWER-CORD
Document #
Title
Type
Download
DRU10162
WaveDriver 200 Electrochemical Workstation User Guide
DRA10052
Probing Fuel Cell Electrocatalyst Properties Using Pine Rotating Disk and Ring-Disk Electrodes

Request a Quote for this Cart

Below is the billing data we have on file. These details will be used on your quotation, so please update them here if you require any changes. Changing any details here updates them for your account.