Pine Research Instrumentation logo

Devanathan-Stachurski Hydrogen Permeation Cell Kit

Part Number
[H2-PERM-CELL]

This hydrogen permeation cell, also known as a Devanathan-Stachurski cell, is used to study corrosion via permeation of hydrogen through a thin disk of metal (typically steel). A complete setup includes two cells, several electrodes/accessories, as well as two fully-floating potentiostats (all sold separately). This setup is designed to meet standards from procedure ASTM G148.

Product Kit

This product is sold as a kit, meaning it consists of multiple independent products used together. View the individual kit products in the tab below.

Login to View Prices

Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.

This hydrogen permeation cell, also known as a Devanathan-Stachurski cell, is used to study corrosion via permeation of hydrogen through a thin disk of metal (typically steel). A complete setup includes two cells, several electrodes/accessories, as well as two fully-floating potentiostats (all sold separately). This setup is designed to meet standards from procedure ASTM G148.

Important
More Detail
Kit Products
Specifications
Performing a Hydrogen Permeation Experiment

A full hydrogen permeation experiment requires at least two Devanathan-Stachurski cells, several electrodes/accessories (see pricing table below for details), as well as two potentiostats. Contact Pine Research for more details regarding implementation and operation of a hydrogen permeation experiment.

Hydrogen permeation experiments often follow the ASTM G148 standard. This Devanathan-Stachurski cell from Pine Research is designed to meet the specifications in ASTM G148. Each borosilicate glass cell holds around 250 mL of electrolyte, has four 14/20 taper ports, and has a #25 spherical joint. A thin metal disk is sandwiched between the spherical joints of two cells, and sealed with O-rings on either side pressed together with a pinch clamp. Pine Research offers 304 stainless steel disks that are 2.13″ (5.40 cm) OD, 0.060″ (0.15 cm) thick; other materials may be available upon request.

The exposed surface area on either side of the disk is approximately 6.95 cm2. Per ASTM G148, the required electrolyte volume per cell should be > 20 mL/cm2, and the recommended ratio of metal disk radius to thickness should be 10:1 or greater. Therefore, using the standard 304 stainless steel disks manufactured by Pine Research with these cells, the ASTM G148 specifications can be satisfied. A minimum volume of 139 mL is required for a surface area of 6.95 cm2 (the cells each hold 250 mL), and the radius to thickness ratio (radius = 1.5 cm; thickness = 0.15 cm) is 10:1.

Operating a hydrogen permeation experiment requires two potentiostats. The typical experimental procedure requires a metal disk acting like the membrane in between the two Devanathan-Stachurski cells, and each half cell also contains a counter electrode and reference electrode (as well as optional Luggin tubes for each reference). Each potentiostat must be fully floating (that is, completely electrically isolated, especially with respect to Earth Ground), and both potentiostats’ Working Drive and Working Sense leads are connected to the metal disk. Each instrument connects to its own counter and reference electrode. One potentiostat generates H2 gas at its counter electrode, which diffuses throughout the electrolyte and permeates through the metal disk. Any H2 that passes through the disk to the other half cell can be detected via oxidation on the opposing counter electrode.

Devanathan-Stachurski Hydrogen Permeation Cell Kit is sold as a product kit. Product kits contain more than one product when purchased. Should you want more details on a specific part in the kit or wish to order an additional or replacement of a component, you can visit the product page for any item in the kit below.
Qty
Image
Product Name
Part #
2
Devanathan-Stachurski Hydrogen Permeation Half Cell (One Half Cell Only)
RRPG361
2
O-Ring, Viton, Round, Size #217
KAA217V
1
Placeholder Image
Pinch Clamp, Size 40
KACP40
2
Dual Port Gas Inlet Accessory, Longer Reach, 14/20 Taper
RRPG376
2
Counter Electrode Assembly, Platinum (Pt), 14/20
AFCTR5
2
Reference Electrode, Silver/Silver Chloride, Single Junction
RREF0021
8
Stopper, PTFE, 14/20 Taper
RRPG085K2
Devanathan-Stachurski Hydrogen Permeation Cell Kit is sold as a product kit. The data below aggregates the specifications for each product contained within the kit..
Devanathan-Stachurski Hydrogen Permeation Cell Kit
Product Kits
Product kit
Kit includes
Cell clamp, Cell stoppers, Counter electrode, Electrochemical cell, Gas sparge/purge tube(s), O-rings, Reference electrode, Working electrode
Devanathan-Stachurski Hydrogen Permeation Half Cell (One Half Cell Only)
Electrochemical Cell
14/20 ports
Cell material
Cell volume (overall, max)
250 mL
Cell water jacket
Cell diameter
7 cm
Cell height
10.5 cm
Cell application
Corrosion, Stationary
Cell compatibility
Standard volume cell series
O-Ring, Viton, Round, Size #217
O-Ring Dimensions
O-ring dash number
217
O-ring material
O-ring cross section shape
Round
O-ring outer diamter (OD)
1 7/16 in
O-ring inner diamter (ID)
1 3/16 in
O-ring width (W)
1/8 in
Reference Electrode, Silver/Silver Chloride, Single Junction
Reference Electrodes
Reference chemistry
Ag/AgCl
Standard potential
+199 mV vs NHE
Reference size type
Reference electrode body diameter
Reference electrode length
19 cm
Reference frit material
External fill solution
4 M KCl with AgCl
Refillable
Typical variance
±3 - 5 mV
Typical input impedance
< 10 kΩ
Reference electrode connection style
1.6 mm OD x 8.5 mm long brass pin
Reference electrode body material