Pine Research Instrumentation logo
Complete RDE System Bundle: WaveDriver 200, WaveVortex 10, E5 Series RDE
Part Number
[WD200-WV10-RDE-E5]

Purchase this product bundle with confidence. The team at Pine Research ensures all components are compatible and designed to work together. This is a complete bundle of everything you need to get started with experiments today. This bundle includes:

This bundle is perfect for a new lab startup, adding a new methodology to your research program or industrial applications, and/or increasing electrochemical exerpiment capacity in your lab.

Product Bundle
This is a product bundle, meaning several compatible products are included together. View the individual bundle products in the tab below.
Product Parts List
This product consists of separately available parts. View the parts list in the tab below.
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.

Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.

Specify Power Cord
This product requires a power cord to connect to AC mains. Please specify the plug style used in your region when you order this product. We stock a variety of power cords.
Includes Free Training Session!
Every purchase of a Pine Research electrochemical workstation includes a free one-hour online training session! Contact Pine Research to inquire about this free session.
Maximum Rotation Rate
All rotating electrodes, including RDE, RRDE, and RCE, have an assigned maximum rotation rate. The maximum rotation rate is specific to each electrode series. Do not exceed the maximum rotation rate when working with rotating electrodes.
Maximum Rotation Rate: 3000 RPM
Never exceed maximum rotation rate when working with rotating electrodes.
Compatibility Notice
Avoid using this reference electrode with the following: NH3 buffers, sulfides, perchlorates, non-aqueous/organic solvents, and alkaline solutions stronger than 0.1M OH.
Chemical Compatibility Caution Notice
PEEK dissolves with long exposure to concentrated acids.
Fragile Material Warning
Platinum wire is fragile. While it can be formed into a shape, repeated bending will cause the wire to break. In almost all cases, this is irreversible and cannot be repaired. Do not bend platinum wire.
Tip: Product Similarity
The WaveDriver 100 is a single channel electrochemical workstation with EIS, whereas the WaveDriver 200 is a two-channel bipotentiostat electrochemical workstation with EIS. The WaveDriver 40 does not have EIS, and is a two-channel bipotentiostat. Other specifications are shared among all current models of the WaveDriver Series.

WaveDriver 200 Electrochemical Workstation

The WaveDriver 200 Electrochemical Workstation is an excellent choice. Unlike other "bipotentiostats" on the market, this workstation electronics features a truly integrated bipotentiostat. You do not have to mess around with cell cables in obscure configurations to operate the workstation as a bipotentiostat. It is ready to use out of the box - just connect your clearly-marked cell cable leads to the desired electrodes and you are ready to go with your experiment, like rotating ring-disk (RRDE). No additional cables, adapters, or connectors required.

The WaveDriver 200 Electrochemical Workstation is engineered to provide the essential hardware and software features you need at an affordable price. It supports a wide range of DC electroanalytical techniques as well as AC techniques such as Electrochemical Impedance Spectroscopy (EIS). It offers current ranges up to ±1 A, potential ranges up to ±15 V, advanced inputs/outputs, waveform filters, EIS up to 1 MHz, and iR compensation. The WaveDriver 200 is a high performance, EIS-capable workstation with integrated bipotentiostat, which is ideal for use with stationary electrodes, RDE, RRDE, and RCE.

AfterMath Blue - Data Acquisition, Analysis, and Organization Software

Licenses for our AfterMath® Blue software are included with the purchase of an Electrochemical Workstation. The licenses give you access to all of the AC and DC methods that the WaveDriver 200 can perform. Pine Research does not charge extra for various categories of electrochemical techniques. If the instrument is capable of a method, you have access to it (no hidden costs). Here are some unique features of AfterMath Blue:

  • Instrument Control. When started, AfterMath automatically detects all compatible instrumentation attached to the computer and provides complete control over each instrument. It can simultaneously control multiple instruments and queue multiple experiments.
  • Flexible Plotting. AfterMath offers a powerful "drag-n-drop" feature for quickly copying and moving traces between plots, with precise control over various plot settings.
  • Scientific Units. Designed with scientific data in mind, AfterMath properly handles units, metric prefixes, and significant figures.
  • Data Archiving. A unique XML-based file format allows multiple related experiments to be stored in a single archive file, simplifying file management.
  • Tools and Transforms. Flexible tools allow precise measurement of quantities like peak height and area, with fundamental mathematical operations available on any trace.

Our talented team of engineers and chemists have taken a careful approach at integrating EIS into our Electrochemical Workstations. Our software engineering team has incorporated EIS equivalent circuit fitting directly into our AfterMath Blue software (no separate software required). Multiple curve fitting algorithms and options allow you to fit even the most troublesome data. Here are some of the exciting and novel EIS analysis features in AfterMath Blue:

  • Integrated Curve Fitting and Analysis. Our software team has seamlessly integrated EIS curve fitting into AfterMath. Why work with more than one software application to fit your EIS data when you can do it using the very same software application that acquired the data? AfterMath EIS curve fitting utilities provide several analyses, including Circuit Fit, Transmission Line, and Kramers-Kronig. Unlike others, our fitting software also provides several fitting methods including Modified Levenberg-Marquardt (LM), Simplex, and Powell algorithms in addition to fitting options that include dynamic point selection, unity, and parametric fitting.
  • Novel Transmission Line Fitting. AfterMath provides a unique approach to model your porous electrodes. While the transmission line model is not new, AfterMath provides you with some unique transmission line fitting tools. Instead of a static circuit, where you have no control over the elements of the model, we provide a very flexible basic model, from which you can customize nearly all aspects of the model to suit your system. Give it a try - import your three- or five-column EIS data directly into AfterMath and see the difference with our transmission line fitting.
  • Finishing Touches. While fitting your EIS data, why flip back and forth between Nyquist and Bode plots? Why not be able to view both plots and fits simultaneously? We heard this feedback from many customers and have designed AfterMath to provide you with both plots simultaneously during fitting. You can also draw your own equivalent circuits to fit your particular system.

WaveVortex 10 Electrode Rotator

The WaveVortex 10 Electrode Rotator is designed to suit the needs of those looking to perform rotating disk (RDE) and rotating ring-disk (RRDE) electrode experiments with limited lab space.  This small footprint rotator is compatible with all 15 mm OD RDE/RRDE electrodes manufactured by Pine Research, along with many of our cells, glassware, and accessories.

The control box, motor, shaft, and enclosure are all fixed into one convenient unit, making the WaveVortex compact and portable.  The rotation rate can be manually adjusted on the front panel and monitored on the digital display.  Alternately, the potentiostat can control the rotation rate using the appropriate rate control cable.

E5 Series Fixed Disk Rotating Disk Electrode (RDE) tip

The E5 Series Glassy Carbon Rotating Disk Electrode (RDE) tip is one of the most common RDE electrodes we offer. This tip features a 15 mm OD PEEK shroud that precision seals against a 5 mm OD, mirror-polished, glassy carbon disk. The tip threads into the shaft installed on the WaveVortex 10. Pine Research offers more electrode in more materials than anybody else. Check out all the other WaveVortex 10 compatible RDE tips we offer

Products Included in this Bundle
Product bundles combine multiple products into one purchase. For details or to purchase additional items, visit the product page for any item below.
Qty
Product Name / Part #
Price
1
WaveVortex 10 Electrode Rotator
AF01WV10
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
1
Rotation Rate Control Interface Cable, for WaveVortex 10 and MSR evo Rotators, WaveDriver Series and WaveNow XV
AKCABLE7-03
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
1
E5 Series Rotating Disk Electrode, Glassy Carbon (GC), PTFE shroud
AFE5T050GC
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
1
Reference Electrode, Silver/Silver Chloride, Single Junction
RREF0021
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
1
Rotating Disk/Ring-Disk Cell Kit, Standard Volume, Water Jacket
AKCELL3
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
1
Bearing Assembly, Gas-Purged, for AFE6MB/AFE9MBA Shaft, PEEK, with 24/25 Taper
AC01TPA6M
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
1
Electrode Polishing Kit
AKPOLISH
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
1
WaveDriver 200/WaveDriver 40 Electrochemical Workstation Cell Cable
ACP3E01
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
1
Counter Electrode Assembly, Platinum (Pt), 14/20
AFCTR5
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
1
WaveDriver 200 Electrochemical Workstation
AFP3
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
Complete RDE System Bundle: WaveDriver 200, WaveVortex 10, E5 Series RDE

Product Bundles

Product Product bundle
Yes
Product Bundle includes
AfterMath Blue Software, Cables, Counter electrode, Electrochemical cell, Electrochemical workstation, Electrode rotator, Power Cord, Reference electrode, Rotating disk working electrode, Rotating Shaft
Product Bundle application
Education, General electrochemistry, Photoelectrochemistry, Rotating Disk (RDE)
Product Bundled electrode rotator
WaveVortex 10
Product Bundled electrochemical workstation
WaveDriver 200
WaveVortex 10 Electrode RotatorView Product

Electrode Rotator

Compatibility

Product Compatible electrode tips
E5 (RDE tip), E6 (RRDE tip), E7 (RRDE tip), E8 (RRDE tip)

Safety & Environmental

Product Rotator RoHS compliant
Yes
Product Rotator safety certification
CE, ETL

Physical

Product Rotator dimensions
380 × 280 × 380 mm (15 × 11 × 15 in) with enclosure window lowered, 380 × 280 × 610 mm (15 × 11 × 24 in) with enclosure window raised
Product Electronics cabinet material
Black powder-coated aluminum
Product Enclosure base and sides materials
Black high-density polyethylene (PE)
Product Enclosure window material
Clear polycarbonate (PC)
Product Operating temperature
10 °C - 40 °C (50 °F - 104 °F)
Product Rotator shipping weight
11 kg (24 lb)
Product Rotator shipping dimensions
41 × 41 × 41 cm (16 × 16 × 16 in)

Rotation Rate

Product Enclosure interlock
Interlock prevents rotation when enclosure window is in raised position. Front panel LED indicates enclosure interlock state.
Product Motor stop connection
Optional digital motor stop input signal on external I/O port, available TTL logic: active high or active low, jumper selectable, front panel LED indicates when external motor stop is active
Product Rate accuracy
100 – 200 RPM: accurate to within ±2 counts of display reading; 200 – 8,000 RPM: accurate to within ±1% of display reading
Product External rate control
Optional rate control via input signal on external I/O port; available control ratios: 1, 2, or 4 RPM/mV, jumper selectable
Product Rate display
4 digit display indicates rotation rate (RPM)
Product Rate output
Optional rate monitoring via output signal on external I/O port; output signal ratio: 2 RPM/mV
Product Rotation rate control
10-turn rotation rate control knob on control unit front panel
Product Start/stop (front panel)
Push-button toggle on front panel with LED indicators for “pause” and “run”

Grounding

Product Rotator chassis terminal
Metal banana jack on motor unit, Second connection provided on external I/O port
Product DC common (analog ground)
Connection provided on external I/O port
Product Rotator earth ground
No direct connection available

Electrical

Product Electrode connections
Disk electrode: red banana jack on motor unit; ring electrode: blue banana jack on motor unit
Product Rotator AC power input
100 - 240 VAC, ±10%, 50/60 Hz, 2 A
Product Rotator DC power supply
24 VDC, 1.5 A (included)
Product Power switch location
Side of unit

Motor

Product Motor bandwidth
Undetermined
Product Control method
Closed loop servo-system (PWM); temperature-compensated tachometer mounted on motor shaft
Product Maximum continuous torque
18.7 mN·m
Product Motor power
11 W
Product Motor protection
Motor current is electronically limited
Product Motor type
Permanent Magnet
Product Slew rate
Undetermined
Rotation Rate Control Interface Cable, for WaveVortex 10 and MSR evo Rotators, WaveDriver Series and WaveNow XVView Product

Cables

Product Cable type
Interface, Signal
Product Cable terminal A type
Plug, Terminal Block, Green, 3-pin
Product Cable terminal B type
Plug, Terminal Block, Green, 8-pin
Product Cable length
3 ft
Product Cable color
Gray
Product Cable instrument compatibility
MSR evo electrode rotator, WaveDriver series electrochemical workstation, WaveNow XV electrochemical workstation, WaveVortex 10 electrode rotator
E5 Series Rotating Disk Electrode, Glassy Carbon (GC), PTFE shroudView Product

Working Electrodes

Disk Electrodes

Product Disk electrode style
Fixed Disk
Product Disk material
Glassy Carbon (GC)
Product Disk crystal lattice
polycrystalline
Product Disk material purity
100%
Product Disk finish
Mirror Polish
Product Disk diameter
5 mm
Product Disk type
Fixed (embedded in electrode tip)
Product Disk series compatibility
None (Fixed Disk)

Electrode Tips

Product Tip maximum rotation rate
3000 RPM
Product Tip shroud material
PTFE
Product Tip shroud diameter
15 mm
Product Tip shroud length
25.4 mm
Product Tip length (overall)
49 mm

Rotating Electrodes

Product Maximum rotation rate
3000 RPM
Product Shaft compatibility
Non-Rotating RDE Shaft (AFE5F), RDE Shaft for ASR Rotator (AFE5A), RDE/RRDE Precision Shaft for MSR Rotator (AFE6MB), RDE/RRDE Shaft for MSR Rotator (AFE6M), RDE/RRDE Shaft for WaveVortex 10 Rotator
Product Rotating electrode type
Fixed Disk Tip
Product Compatible electrode rotator(s)
ASR Rotator (AFASR), MSR evo Rotator (AFMSR24), MSR Rotator (AFMSRCE), MSRX Rotator (AFMSRX), WaveVortex 10 Rotator (AF01WV10)

General

Product Electrode series
E5
Product Thermal stability range
10°C - 25°C
Product Electrode use/application
Rotating Disk (RDE)
Reference Electrode, Silver/Silver Chloride, Single JunctionView Product

Reference Electrodes

Product Reference chemistry
Ag/AgCl
Product Standard potential
+199 mV vs NHE
Product Reference size type
Standard (9.5 mm OD)
Product Reference electrode body diameter
9.5 mm
Product Reference electrode length
19 cm
Product Reference frit material
Ceramic
Product External fill solution
4 M KCl with AgCl
Product Refillable
yes
Product Typical variance
±3 - 5 mV
Product Typical input impedance
< 10 kΩ
Product Reference electrode connection style
1.6 mm OD x 8.5 mm long brass pin
Product Reference electrode body material
borosilicate glass
WaveDriver 200/WaveDriver 40 Electrochemical Workstation Cell CableView Product

Cables

Product Cable type
Workstation cell cable
Product Cable terminal A type
Plug, D-SUB 17-pin + 7 Coax
Product Cable length
3 ft
Product Cable color
Black
Product Cable instrument compatibility
WaveDriver 200 electrochemical workstation, WaveDriver 40 electrochemical workstation

Workstation Cell Cable

Product Number of cell cable leads
Seven (7)
Product Cell cable lead colors
Counter/Auxiliary [GREEN], Instrument Chassis (ground) [GRAY], Reference [WHITE], Working 1 (drive) [RED], Working 1 (sense) [ORANGE], Working 2 (drive) [BLUE], Working 2 (sense) [VIOLET]
Product Cell cable lead termination
Banana Plug (4 mm)
Product Cell cable shielded lines
Counter, Reference, Working 1 (drive), Working 1 (sense), Working 2 (drive), Working 2 (sense)
WaveDriver 40/100/200 Power SupplyView Product

Workstation Compatibility

Product Compatible electrochemical workstation
WaveDriver 100 (AFP5), WaveDriver 200 (AFP3), WaveDriver 40 (AFP4)

Electrochemical Workstations

General

Product Power supply input
100 - 240 VAC, 1.4 - 0.7 A, 50 - 60 Hz
Product Power supply output
24 VDC, 5.0 A power supply (included) has a C14 type input connector
Product Power cord
Various international cables sold separately (C13 type)
Power CordsView Product
WaveVortex 10 Rotating ShaftView Product

Electrode Shafts

Product Shaft length (overall)
126 mm (4.95 in)
Product Shaft shroud diameter
15 mm
Product Shaft shroud length
66 mm
Product Shaft shroud material
PEEK
Product Shaft rotator compatibility
WaveVortex 10 Rotator (AF01WV10)

Electrode Rotator

Applications

Product Rotating application
Rotating Disk (RDE), Rotating Ring-Disk (RRDE)

Compatibility

Product Compatible electrode tips
E5 (RDE tip), E6 (RRDE tip), E7 (RRDE tip), E8 (RRDE tip)
Counter Electrode Assembly, Platinum (Pt), 14/20View Product

Counter Electrodes

Product Counter electrode size type
Standard (9.5 mm - 12 mm OD)
Product Counter body diameter
6.4 mm (shroud)
Product Counter length
180 mm
Product Counter electrode material
Platinum Wire
Product Counter electrode connection style
1.5 mm OD x 7 mm long gold-plated pin
Product Counter electrode wire diameter
0.5 mm
Product Counter electrode wire surface area
4.7 cm²
Product Counter electrode platinum mass
1.3 g
Product Counter electrode adapter
12 mm to 14/20 Joint, 6.4 mm to 14/20 Joint
Product Counter electrode isolation tube frit
Ace Glass Frit D (10 – 20 µm)
Product Counter electrode isolation tube diameter
12 mm
Product Counter shroud material
Epoxy
WaveDriver 200 Electrochemical WorkstationView Product

Electrode Rotator

Safety & Environmental

Product Rotator RoHS compliant
Yes
Product Rotator safety certification
CE, ETL

Electrochemical Workstations

Communication

Product Interface
USB
Product Wireless capable
No

General

Product Power input
24 VDC (±5%), 5.0 A (low voltage DC device)
Product Power supply input
100 - 240 VAC, 1.4 - 0.7 A, 50 - 60 Hz
Product Power supply output
24 VDC, 5.0 A power supply (included) has a C14 type input connector
Product Power cord
Various international cables sold separately (C13 type)
Product LED indicators
Power, USB, and status
Product Instrument dimensions
160 × 324 × 255 mm (6.3 × 12.75 × 10.0 in)
Product Workstation shipping dimensions
254 × 356 × 457 mm (10 × 14 × 18 in)
Product Instrument weight
4.6 kg (10.2 lb)
Product Workstation shipping weight
7.7 kg (17 lb)
Product Temperature range
10°C - 40°C
Product Humidity range
80% RH maximum, non-condensing
Product Workstation modes
Galvanostat (GAL), Open-Circuit Potential (OCP), Potentiostat (POT), Zero-Resistance Ammeter (ZRA)

Auxiliary Connections

Product Connector C
9-pin DSUB connector that includes DC Common, two digital output signals, and two digital input signals
Product Trigger input
BNC female, TTL compatible
Product Trigger output
BNC female, TTL compatible
Product Potential (E1) output
BNC female, ±15 V, ±10 V, ±2.5 V output, ±0.5% accuracy
Product Current (I1) output
BNC female, ±10 V output, scaled to current range, ±0.5% accuracy
Product Potential (E2) output
BNC female, ±15 V, ±10 V, ±2.5 V output, ±0.5% accuracy
Product Current (I2) output
BNC female, ±10 V output, scaled to current range, ±0.5% accuracy
Product Auxiliary analog input
BNC female, ±10 V differential input, 313 µV resolution, 0.2% accuracy (available when second working electrode not in use)
Product Auxiliary analog output
BNC female, ±10 V bipolar output, 313 µV resolution, 0.2% accuracy (available when second working electrode not in use)
Product WK1 input
BNC female, ±10V differential input, 20 kΩ impedance, ±0.5% accuracy; allows external waveform to be summed directly to the working electrode excitation signal
Product WK2 input
BNC female, ±10V differential input, 20 kΩ impedance, ±0.5% accuracy; allows external waveform to be summed directly to the working electrode excitation signal

Accessories

Product Dummy cell
External dummy cell included
Product Cell cable
Combination D-SUB connector to multiple banana plugs via shielded coaxial cables (included)

Rotator Control Connections

Product Rotator connector A
7-pin mini circular DIN includes analog and digital signal grounds, digital rotator enable signal (+15 V max), auxiliary digital output signal, and analog rotation rate control signal
Product Rotator connector B
3-pin connector includes analog signal ground, digital rotator enable signal (+15 V max), and analog rotation rate control signal
Product Rate control signal
±10 V, ±2.5 V
Product Digital enable signal
Open drain with 4.7 kΩ pull up to +5 V (TTL compatible)

Electrochemical Impedance Spectroscopy (EIS)

Product EIS capable
Yes
Product EIS frequency range
10 µHz - 1 MHz
Product EIS frequency resolution
<1 ppm 1 MHz - 100 mHz, <70 ppm 1 mHz - 10 µHz, <80 ppm 100 mHz - 10 mHz, <90 ppm 10 mHz - 1 mHz
Product EIS frequency stability
±10 ppm
Product Modes
Galvanostatic, Potentiostatic
Product Voltage excitation setpoint
1 mV - 200 mV peak, ±10% of setting
Product Current excitation setpoint
0.01% - 100% of current range, 10% of setting, 200 mA maximum
Product Frequency sweeping
Custom list, Linear, Logarithmic
Product EIS accuracy
EIS Accuracy Contour Plot

Data Acquisition (for DC Experiments)

Product Clock resolution
10 ns (minimum time base)
Product Point interval
80 µs (minimum)
Product Synchronization
Simultaneous sampling of all analog input signals
Product Raw point total
<10 million per experiment

Applied Potential (Potentiostatic Mode)

Product Potential ranges (applied)
±10 V, ±15 V, ±2.5 V
Product DC accuracy (potential, applied)
±0.2% of setting; ±0.05% of range
Product DAC output (potential)
16 bits
Product CV sweep rate (minimum)
10 µV/s
Product CV sweep rate (maximum)
75 V/s

Measured Potential

Product Potential ranges (measured)
±10 V, ±15 V, ±2.5 V
Product DC accuracy (potential, measured)
±0.2% of setting; ±0.05% of range
Product ADC output
16 bits
Product Filters (for DC Experiments)
100 kHz, 1 kHz, 100 Hz, 30 Hz, 10 Hz

Electrometer (Reference Electrode Amplifier)

Product Input impedance
>10¹² in parallel with <10 pF
Product Input current
<10 pA leakage/bias current at 25°C
Product CMRR
>100 dB, 0 - 1 kHz, >40 dB ≤ 1 MHz, >60 dB ≤100 kHz, >80 dB ≤10 kHz
Product Electrometer bandwidth
>15 MHz (3 dB)

Power Amplifier (Counter Electrode Amplifier)

Product Output current
±1 A (maximum)
Product Short circuit current limit
10 mA - 100 nA ranges: <200 mA, 1A, 100 mA ranges: <1.3 A
Product Compliance voltage
±17 V
Product Bandwidth
>2.5 MHz (on fastest speed setting)
Product Noise and ripple
<35 µV RMS in 2 MHz bandwidth
Product Slew rate/rise time
10 V/µs (on fastest speed setting)

Applied Current (Galvanostatic Mode)

Product Current ranges (applied)
±1 A, ±100 mA, ±10 mA, ±1 mA, ±100 µA, ±10 µA, ±1 µA, ±100 nA
Product DC accuracy (current, applied)
±0.2% of setting; ±0.05% of range

Measured Current (Potentiostatic Mode)

Product Current ranges (measured)
±1 A, ±100 mA, ±10 mA, ±1 mA, ±100 µA, ±10 µA, ±1 µA, ±100 nA
Product Current resolution at each range (measured)
31.3 µA, 3.13 µA, 313 nA, 31.3 nA, 3.13 nA, 313 pA, 31.3 pA, 3.13 pA
Product Autoranging
Yes
Product Practical current range
20 pA to 1 A
Product DC accuracy (current, measured)
±0.2% of setting; ±0.05% of range
Product DC leakage current
<10 pA at 25°C
Product AC accuracy (measured)
Frequency- and range-dependent to 1 MHz
Product AC leakage current
Frequency- and range-dependent to 1 MHz
Product ADC input
16 bits
Product Filters (for DC Experiments)
100 kHz, 1 kHz, 100 Hz, 30 Hz, 10 Hz

Ground Connections

Product DC common (signal)
The DC Common is isolated from the USB port, the instrument chassis and earth ground. The DC Common is accessible via a banana binding post (black) on the back panel.
Product Chassis terminal
The instrument chassis terminal is accessible via a banana binding post (metal) on the back panel. The GRAY banana plug on the cell cable also provides a chassis connection.
Product Earth
No direct connection to earth ground is provided.

Electrode Connections

Product Reference electrode
Sense line with driven shield
Product Counter electrode
Drive line with grounded shield
Product Working electrode channels
2 Channels
Product Working electrode #1 (WK1)
Separate sense and drive lines, each with driven shield (current measurement via passive shunt)
Product Working electrode #2 (WK2)
Separate sense and drive lines, each with driven shield (current measurement via transimpedance amplifier). Note: AC techniques are not available on WK2.
Replacement Parts & Accessories
Customers may wish to order replacement or additional components of this product. Should you want more details or wish to order an additional part, refer to the list below.
Qty
Product Name / Part #
Price
1
WaveDriver 200/WaveDriver 40 Electrochemical Workstation Cell Cable
ACP3E01
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
1
Universal Dummy Cell, Modular
AFDUM9
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
1
WaveDriver 40/100/200 Power Supply
RRPA24V5A
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
1
Power Cords
POWER-CORD
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
2
WaveVortex 10 Standard Brush Assembly
AC01WV10S05
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
2
WaveVortex 10 Low-Humidity Brush Assembly
AC01WV10S05LH
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
1
WaveVortex 10 Rotating Shaft
AC01WV10S07
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
1
WaveVortex 10 Power Supply
EE24V17A
Login to View Prices
Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.
Product Documentation
DRK10062
Electrode Compatibility And Application Overview
DRP10095
Gas-Purged Bearing Assembly Product Guide
DRK10135
Electrode Shroud Materials
DRA10052
Probing Fuel Cell Electrocatalyst Properties Using Pine Rotating Disk and Ring-Disk Electrodes
DRK10013
Pine Research Electrode Polishing Guide
DRP10014
Glassy Carbon Electrode Information
DRU10158
WaveVortex 10 Electrode Rotator User Guide
DRP10046
E5PK Series RDE (PEEK) Tip Product Guide
DRU10162
WaveDriver 200 Electrochemical Workstation User Guide
Safety Data Sheets (SDS)
For this product, any applicable SDS will be listed here by category. You can view or download the SDS by clicking the appropriate button.

Carbon Materials

Glassy Carbon (GC)

Electrode Polishing Materials

0.3 µm Aluminum Oxide Suspension (Alumina)
0.05 µm Aluminum Oxide Suspension (Alumina)
5 µm Aluminum Oxide Suspension (Alumina)
Grinding Disk

Reference Electrode Filling Solutions

4 M Potassium Chloride with Silver Chloride (KCl with AgCl)
Login
Register
Lost Password

Please enter your username (email address) and password below.

Confirm Logout

Are you sure you want to log out?

Request a Quote for this Cart

Below is the billing data we have on file. These details will be used on your quotation, so please update them here if you require any changes. Changing any details here updates them for your account.