Pine Research Instrumentation logo

Complete RRDE System Bundle: WaveDriver 200, WaveVortex 10, E8R4 Series RRDE

Part Number
[WD200-WV10-RRDE-E8R4]

Purchase this product bundle with confidence. The team at Pine Research ensures all components are compatible and designed to work together. This is a complete bundle of everything you need to get started with experiments today. This bundle includes:

This bundle is perfect for a new lab startup, adding a new methodology to your research program or industrial applications, and/or increasing electrochemical exerpiment capacity in your lab.

Product Bundle

This is a product bundle, meaning several compatible products are included together. View the individual bundle products in the tab below.

Login to View Prices

Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.

Purchase this product bundle with confidence. The team at Pine Research ensures all components are compatible and designed to work together. This is a complete bundle of everything you need to get started with experiments today. This bundle includes:

This bundle is perfect for a new lab startup, adding a new methodology to your research program or industrial applications, and/or increasing electrochemical exerpiment capacity in your lab.

Important
More Detail
Bundle Products
Specifications
Documents
SDS
Specify Power Cord

This product requires a power cord to connect to AC mains. Please specify the plug style used in your region when you order this product. We stock a variety of power cords.

Includes Free Training Session!

Every purchase of a WaveDriver 100 electrochemical workstation includes a free one-hour online training session! Contact Pine Research to inquire about this free session.

Maximum Rotation Rate

All rotating electrodes, including RDE, RRDE, and RCE, have an assigned maximum rotation rate. The maximum rotation rate is specific to each electrode series. Do not exceed the maximum rotation rate when working with rotating electrodes.

Maximum Rotation Rate: 3000 RPM

Never exceed maximum rotation rate when working with rotating electrodes.

Compatibility Notice

Avoid using this reference electrode with the following: NH3 buffers, sulfides, perchlorates, non-aqueous/organic solvents, and alkaline solutions stronger than 0.1M OH.

Chemical Compatibility Caution Notice

PEEK dissolves with long exposure to concentrated acids.

Fragile Material Warning

Platinum wire is fragile. While it can be formed into a shape, repeated bending will cause the wire to break. In almost all cases, this is irreversible and cannot be repaired. Do not bend platinum wire.

Consumable U-Cups!

The PTFE U-Cup is a consumable product for the ChangeDisk RDE and RRDE tips. To ensure proper operation and longevity of the tip, Pine Research recommends replacing the U-Cup every 4-5 times you perform a ChangeDisk operation. Permanent, irreversible damage to the tip will result if the U-Cup is not regularly changed. Consider purchase a backup supply when ordering a new ChangeDisk RDE or RRDE tip.

WaveDriver 200 Electrochemical Workstation

The WaveDriver 200 Electrochemical Workstation is an excellent choice. Unlike other "bipotentiostats" on the market, this workstation electronics features a truly integrated bipotentiostat. You do not have to mess around with cell cables in obscure configurations to operate the workstation as a bipotentiostat. It is ready to use out of the box - just connect your clearly-marked cell cable leads to the desired electrodes and you are ready to go with your experiment, like rotating ring-disk (RRDE). No additional cables, adapters, or connectors required.

The WaveDriver 200 Electrochemical Workstation is engineered to provide the essential hardware and software features you need at an affordable price. It supports a wide range of DC electroanalytical techniques as well as AC techniques such as Electrochemical Impedance Spectroscopy (EIS). It offers current ranges up to ±1 A, potential ranges up to ±15 V, advanced inputs/outputs, waveform filters, EIS up to 1 MHz, and iR compensation. The WaveDriver 200 is a high performance, EIS-capable workstation with integrated bipotentiostat, which is ideal for use with stationary electrodes, RDE, RRDE, and RCE.

AfterMath Blue - Data Acquisition, Analysis, and Organization Software

Licenses for our AfterMath® Blue software are included with the purchase of an Electrochemical Workstation. The licenses give you access to all of the AC and DC methods that the WaveDriver 200 can perform. Pine Research does not charge extra for various categories of electrochemical techniques. If the instrument is capable of a method, you have access to it (no hidden costs). Here are some unique features of AfterMath Blue:

  • Instrument Control. When started, AfterMath automatically detects all compatible instrumentation attached to the computer and provides complete control over each instrument. It can simultaneously control multiple instruments and queue multiple experiments.
  • Flexible Plotting. AfterMath offers a powerful "drag-n-drop" feature for quickly copying and moving traces between plots, with precise control over various plot settings.
  • Scientific Units. Designed with scientific data in mind, AfterMath properly handles units, metric prefixes, and significant figures.
  • Data Archiving. A unique XML-based file format allows multiple related experiments to be stored in a single archive file, simplifying file management.
  • Tools and Transforms. Flexible tools allow precise measurement of quantities like peak height and area, with fundamental mathematical operations available on any trace.

Our talented team of engineers and chemists have taken a careful approach at integrating EIS into our Electrochemical Workstations. Our software engineering team has incorporated EIS equivalent circuit fitting directly into our AfterMath Blue software (no separate software required). Multiple curve fitting algorithms and options allow you to fit even the most troublesome data. Here are some of the exciting and novel EIS analysis features in AfterMath Blue:

  • Integrated Curve Fitting and Analysis. Our software team has seamlessly integrated EIS curve fitting into AfterMath. Why work with more than one software application to fit your EIS data when you can do it using the very same software application that acquired the data? AfterMath EIS curve fitting utilities provide several analyses, including Circuit Fit, Transmission Line, and Kramers-Kronig. Unlike others, our fitting software also provides several fitting methods including Modified Levenberg-Marquardt (LM), Simplex, and Powell algorithms in addition to fitting options that include dynamic point selection, unity, and parametric fitting.
  • Novel Transmission Line Fitting. AfterMath provides a unique approach to model your porous electrodes. While the transmission line model is not new, AfterMath provides you with some unique transmission line fitting tools. Instead of a static circuit, where you have no control over the elements of the model, we provide a very flexible basic model, from which you can customize nearly all aspects of the model to suit your system. Give it a try - import your three- or five-column EIS data directly into AfterMath and see the difference with our transmission line fitting.
  • Finishing Touches. While fitting your EIS data, why flip back and forth between Nyquist and Bode plots? Why not be able to view both plots and fits simultaneously? We heard this feedback from many customers and have designed AfterMath to provide you with both plots simultaneously during fitting. You can also draw your own equivalent circuits to fit your particular system.

WaveVortex 10 Electrode Rotator

The WaveVortex 10 Electrode Rotator is designed to suit the needs of those looking to perform rotating disk (RDE) and rotating ring-disk (RRDE) electrode experiments with limited lab space.  This small footprint rotator is compatible with all 15 mm OD RDE/RRDE electrodes manufactured by Pine Research, along with many of our cells, glassware, and accessories.

The control box, motor, shaft, and enclosure are all fixed into one convenient unit, making the WaveVortex compact and portable.  The rotation rate can be manually adjusted on the front panel and monitored on the digital display.  Alternately, the potentiostat can control the rotation rate using the appropriate rate control cable.

E8R4 Series High Efficiency Fixed Disk Rotating Ring-Disk Electrode (RRDE) tip

The E8R4 Series High Efficiency Rotating Ring-Disk Electrode (RRDE) with Platinum Ring and Glassy Carbon Disk has the highest collection efficiency of any RRDE electrode on the market, 43.9%! This tip features a 15 mm OD PEEK shroud, 5 mm OD glassy carbon disk, and 1.25 mm thick platinum ring. The tip threads into the shaft installed on the WaveVortex 10. Pine Research offers more electrode in more materials than anybody else. Check out all the other WaveVortex 10 compatible RRDE tips we offer

Complete RRDE System Bundle: WaveDriver 200, WaveVortex 10, E8R4 Series RRDE is sold as a product bundle. Product bundles combine multiple products into one purchase. For details or to purchase additional items, visit the product page for any item in the bundle below.
Qty
Image
Product Name
Part #
1
WaveDriver 200 Bipotentiostat/Galvanostat with EIS Electrochemical Impedance Spectroscopy
WaveDriver 200 Electrochemical Workstation
AFP3
1
WaveVortex 10 Electrode Rotator
AF01WV10
1
Rotation Rate Control Interface Cable, for WaveVortex 10 and MSR evo Rotators, WaveDriver Series and WaveNow XV
AKCABLE7-03
1
E8 Series Fixed-Disk High Efficiency Rotating Ring-Disk Electrode, Glassy Carbon (GC) Disk, Platinum (Pt) Ring, PTFE separator, PEEK shroud
AFE8R4GCPT
1
Counter Electrode Assembly, Platinum (Pt), 14/20
AFCTR5
1
Reference Electrode, Silver/Silver Chloride, Single Junction
RREF0021
1
Rotating Disk/Ring-Disk Cell Kit, Standard Volume, Water Jacket
AKCELL3
1
Bearing Assembly, Gas-Purged, for AFE6MB/AFE9MBA Shaft, PEEK, with 24/25 Taper
AC01TPA6M
1
Electrode Polishing Kit
AKPOLISH
Complete RRDE System Bundle: WaveDriver 200, WaveVortex 10, E8R4 Series RRDE is sold as a product bundle. The data below aggregates the specifications for each product contained within the bundle..
Complete RRDE System Bundle: WaveDriver 200, WaveVortex 10, E8R4 Series RRDE
Product Bundles
Product bundle
Bundle application
Education, General electrochemistry, Photoelectrochemistry, Rotating Disk (RDE), Rotating Ring-Disk (RRDE)
Bundled electrode rotator
Bundled electrochemical workstation
WaveDriver 200 Electrochemical Workstation
Electrochemical Workstations
Electrode Connections
Reference electrode
Sense line with driven shield
Counter electrode
Drive line with grounded shield
Working electrode channels
Working electrode #1 (WK1)
Separate sense and drive lines, each with driven shield (current measurement via passive shunt)
Working electrode #2 (WK2)
Separate sense and drive lines, each with driven shield (current measurement via transimpedance amplifier). Note: AC techniques are not available on WK2.
Ground Connections
DC common (signal)
The DC Common is isolated from the USB port, the instrument chassis and earth ground. The DC Common is accessible via a banana binding post (black) on the back panel.
Chassis terminal
The instrument chassis terminal is accessible via a banana binding post (metal) on the back panel. The GRAY banana plug on the cell cable also provides a chassis connection.
Earth
No direct connection to earth ground is provided.
Measured Current (Potentiostatic Mode)
Current ranges (measured)
±1 A, ±100 mA, ±10 mA, ±1 mA, ±100 µA, ±10 µA, ±1 µA, ±100 nA
Current resolution at each range (measured)
31.3 µA, 3.13 µA, 313 nA, 31.3 nA, 3.13 nA, 313 pA, 31.3 pA, 3.13 pA
Autoranging
Yes
Practical current range
20 pA to 1 A
DC accuracy (current, measured)
±0.2% of setting; ±0.05% of range
DC leakage current
<10 pA at 25°C
AC accuracy (measured)
Frequency- and range-dependent to 1 MHz
AC leakage current
Frequency- and range-dependent to 1 MHz
ADC input
16 bits
Filters (for DC Experiments)
100 kHz, 1 kHz, 100 Hz, 30 Hz, 10 Hz
Applied Current (Galvanostatic Mode)
Current ranges (applied)
±1 A, ±100 mA, ±10 mA, ±1 mA, ±100 µA, ±10 µA, ±1 µA, ±100 nA
DC accuracy (current, applied)
±0.2% of setting; ±0.05% of range
Power Amplifier (Counter Electrode Amplifier)
Output current
±1 A (maximum)
Short circuit current limit
10 mA - 100 nA ranges: <200 mA, 1A, 100 mA ranges: <1.3 A
Compliance voltage
±17 V
Bandwidth
>2.5 MHz (on fastest speed setting)
Noise and ripple
<35 µV RMS in 2 MHz bandwidth
Slew rate/rise time
10 V/µs (on fastest speed setting)
Electrometer (Reference Electrode Amplifier)
Input impedance
>10¹² in parallel with <10 pF
Input current
<10 pA leakage/bias current at 25°C
CMRR
>100 dB, 0 - 1 kHz, >40 dB ≤ 1 MHz, >60 dB ≤100 kHz, >80 dB ≤10 kHz
Electrometer bandwidth
>15 MHz (3 dB)
Measured Potential
DC accuracy (potential, measured)
±0.2% of setting; ±0.05% of range
ADC output
16 bits
Filters (for DC Experiments)
100 kHz, 1 kHz, 100 Hz, 30 Hz, 10 Hz
Applied Potential (Potentiostatic Mode)
DC accuracy (potential, applied)
±0.2% of setting; ±0.05% of range
DAC output (potential)
16 bits
CV sweep rate (minimum)
10 µV/s
CV sweep rate (maximum)
75 V/s
Data Acquisition (for DC Experiments)
Clock resolution
10 ns (minimum time base)
Point interval
80 µs (minimum)
Synchronization
Simultaneous sampling of all analog input signals
Raw point total
<10 million per experiment
Electrochemical Impedance Spectroscopy (EIS)
EIS capable
EIS frequency range
10 µHz - 1 MHz
EIS frequency resolution
<1 ppm 1 MHz - 100 mHz, <70 ppm 1 mHz - 10 µHz, <80 ppm 100 mHz - 10 mHz, <90 ppm 10 mHz - 1 mHz
EIS frequency stability
±10 ppm
Modes
Galvanostatic, Potentiostatic
Voltage excitation setpoint
1 mV - 200 mV peak, ±10% of setting
Current excitation setpoint
0.01% - 100% of current range, 10% of setting, 200 mA maximum
Frequency sweeping
Custom list, Linear, Logarithmic
EIS accuracy
Rotator Control Connections
Rotator connector A
7-pin mini circular DIN includes analog and digital signal grounds, digital rotator enable signal (+15 V max), auxiliary digital output signal, and analog rotation rate control signal
Rotator connector B
3-pin connector includes analog signal ground, digital rotator enable signal (+15 V max), and analog rotation rate control signal
Rate control signal
±10 V, ±2.5 V
Digital enable signal
Open drain with 4.7 kΩ pull up to +5 V (TTL compatible)
Accessories
Dummy cell
External dummy cell included
Cell cable
Combination D-SUB connector to multiple banana plugs via shielded coaxial cables (included)
Auxiliary Connections
Connector C
9-pin DSUB connector that includes DC Common, two digital output signals, and two digital input signals
Trigger input
BNC female, TTL compatible
Trigger output
BNC female, TTL compatible
Potential (E1) output
BNC female, ±15 V, ±10 V, ±2.5 V output, ±0.5% accuracy
Current (I1) output
BNC female, ±10 V output, scaled to current range, ±0.5% accuracy
Potential (E2) output
BNC female, ±15 V, ±10 V, ±2.5 V output, ±0.5% accuracy
Current (I2) output
BNC female, ±10 V output, scaled to current range, ±0.5% accuracy
Auxiliary analog input
BNC female, ±10 V differential input, 313 µV resolution, 0.2% accuracy (available when second working electrode not in use)
Auxiliary analog output
BNC female, ±10 V bipolar output, 313 µV resolution, 0.2% accuracy (available when second working electrode not in use)
WK1 input
BNC female, ±10V differential input, 20 kΩ impedance, ±0.5% accuracy; allows external waveform to be summed directly to the working electrode excitation signal
WK2 input
BNC female, ±10V differential input, 20 kΩ impedance, ±0.5% accuracy; allows external waveform to be summed directly to the working electrode excitation signal
General
Power input
24 VDC (±5%), 5.0 A (low voltage DC device)
Power supply input
100 - 240 VAC, 1.4 - 0.7 A, 50 - 60 Hz
Power supply output
24 VDC, 5.0 A power supply (included) has a C14 type input connector
Power cord
Various international cables sold separately (C13 type)
LED indicators
Power, USB, and status
Instrument dimensions
160 × 324 × 255 mm (6.3 × 12.75 × 10.0 in)
Workstation shipping dimensions
254 × 356 × 457 mm (10 × 14 × 18 in)
Instrument weight
4.6 kg (10.2 lb)
Workstation shipping weight
7.7 kg (17 lb)
Temperature range
10°C - 40°C
Humidity range
80% RH maximum, non-condensing
Workstation modes
Galvanostat (GAL), Open-Circuit Potential (OCP), Potentiostat (POT), Zero-Resistance Ammeter (ZRA)
Communication
Interface
Wireless capable
Electrode Rotator
Safety & Environmental
Rotator RoHS compliant
Yes
Rotator safety certification
CE, ETL
WaveVortex 10 Electrode Rotator
Electrode Rotator
Motor
Motor bandwidth
Undetermined
Control method
Closed loop servo-system (PWM); temperature-compensated tachometer mounted on motor shaft
Maximum continuous torque
18.7 mN·m
Motor power
11 W
Motor protection
Motor current is electronically limited
Motor type
Permanent Magnet
Slew rate
Undetermined
Electrical
Electrode connections
Disk electrode: red banana jack on motor unit; ring electrode: blue banana jack on motor unit
Rotator AC power input
100 - 240 VAC, ±10%, 50/60 Hz, 2 A
Rotator DC power supply
24 VDC, 1.5 A (included)
Power switch location
Side of unit
Grounding
Rotator chassis terminal
Metal banana jack on motor unit, Second connection provided on external I/O port
DC common (analog ground)
Connection provided on external I/O port
Rotator earth ground
No direct connection available
Rotation Rate
Enclosure interlock
Interlock prevents rotation when enclosure window is in raised position. Front panel LED indicates enclosure interlock state.
Motor stop connection
Optional digital motor stop input signal on external I/O port, available TTL logic: active high or active low, jumper selectable, front panel LED indicates when external motor stop is active
Rate accuracy
100 – 200 RPM: accurate to within ±2 counts of display reading; 200 – 8,000 RPM: accurate to within ±1% of display reading
External rate control
Optional rate control via input signal on external I/O port; available control ratios: 1, 2, or 4 RPM/mV, jumper selectable
Rate display
4 digit display indicates rotation rate (RPM)
Rate output
Optional rate monitoring via output signal on external I/O port; output signal ratio: 2 RPM/mV
Rotation rate control
10-turn rotation rate control knob on control unit front panel
Start/stop (front panel)
Push-button toggle on front panel with LED indicators for “pause” and “run”
Physical
Rotator dimensions
380 × 280 × 380 mm (15 × 11 × 15 in) with enclosure window lowered, 380 × 280 × 610 mm (15 × 11 × 24 in) with enclosure window raised
Electronics cabinet material
Black powder-coated aluminum
Enclosure base and sides materials
Black high-density polyethylene (PE)
Enclosure window material
Clear polycarbonate (PC)
Operating temperature
10 °C - 40 °C (50 °F - 104 °F)
Rotator shipping weight
11 kg (24 lb)
Rotator shipping dimensions
41 × 41 × 41 cm (16 × 16 × 16 in)
Safety & Environmental
Rotator RoHS compliant
Yes
Rotator safety certification
CE, ETL
Compatibility
Rotation Rate Control Interface Cable, for WaveVortex 10 and MSR evo Rotators, WaveDriver Series and WaveNow XV
Cables
Cable type
Interface, Signal
Cable terminal A type
Plug, Terminal Block, Green, 3-pin
Cable terminal B type
Plug, Terminal Block, Green, 8-pin
Cable length
3 ft
Cable color
Gray
Cable instrument compatibility
MSR evo electrode rotator, WaveDriver series electrochemical workstation, WaveNow XV electrochemical workstation, WaveVortex 10 electrode rotator
E8 Series Fixed-Disk High Efficiency Rotating Ring-Disk Electrode, Glassy Carbon (GC) Disk, Platinum (Pt) Ring, PTFE separator, PEEK shroud
Working Electrodes
General
Electrode series
Thermal stability range
10°C - 80°C
Electrode use/application
Rotating Ring-Disk (RRDE)
Electrode Tips
Tip maximum rotation rate
3000 RPM
Tip shroud material
Tip shroud diameter
Tip shroud length
25.4 mm
Tip length (overall)
49 mm
Disk Electrodes
Disk electrode style
Disk material
Disk crystal lattice
polycrystalline
Disk material purity
100%
Disk finish
Mirror Polish
Disk diameter
Disk series compatibility
None (Fixed Disk)
Ring Electrodes
Ring material
Ring crystal lattice
Polycrystalline
Ring material purity
99.99%
Ring finish
Mirror Polish
Ring outer diameter
8.5 mm
Ring inner diameter
6 mm
Ring thickness
1.25 mm
Ring disk gap
0.5 mm
Ring disk separator material
Collection efficiency
43.9%
Reference Electrode, Silver/Silver Chloride, Single Junction
Reference Electrodes
Reference chemistry
Ag/AgCl
Standard potential
+199 mV vs NHE
Reference size type
Reference electrode body diameter
Reference electrode length
19 cm
Reference frit material
External fill solution
4 M KCl with AgCl
Refillable
Typical variance
±3 - 5 mV
Typical input impedance
< 10 kΩ
Reference electrode connection style
1.6 mm OD x 8.5 mm long brass pin
Reference electrode body material
Document #
Title
Type
Download
DRK10062
Electrode Compatibility And Application Overview
DRP10095
Gas-Purged Bearing Assembly Product Guide
DRK10135
Electrode Shroud Materials
DRA10052
Probing Fuel Cell Electrocatalyst Properties Using Pine Rotating Disk and Ring-Disk Electrodes
DRK10013
Pine Research Electrode Polishing Guide
DRP10014
Glassy Carbon Electrode Information
DRU10158
WaveVortex 10 Electrode Rotator User Guide
DRP10216
E8 Series High Efficiency Rotating Ring-Disk Electrode Information
DRU10162
WaveDriver 200 Electrochemical Workstation User Guide
For this product, any applicable SDS will be listed here by category. You can view or download the SDS by clicking the appropriate button.
Elemental Metals
Platinum (Pt)