Complete RDE System Bundle: WaveNow Wireless, MSR evo, E5TQ Series RDE

Purchase this product bundle with confidence. The team at Pine Research ensures all components are compatible and designed to work together. This is a complete bundle of everything you need to get started with experiments today. This bundle includes:

This bundle is perfect for a new lab startup, adding a new methodology to your research program or industrial applications, and/or increasing electrochemical exerpiment capacity in your lab.

Product Information

Important Product Warnings and Notices

Specify Power Cord
This product requires a power cord to connect to AC mains. Please specify the plug style used in your region when you order this product. We stock a variety of power cords.
Includes Free Training Session!
Every purchase of a Pine Research electrochemical workstation includes a free one-hour online training session! Contact Pine Research to inquire about this free session.
Maximum Rotation Rate
All rotating electrodes, including RDE, RRDE, and RCE, have an assigned maximum rotation rate. The maximum rotation rate is specific to each electrode series. Do not exceed the maximum rotation rate when working with rotating electrodes.
Maximum Rotation Rate: 3000 RPM
Never exceed maximum rotation rate when working with rotating electrodes.
Compatibility Notice
Avoid using this reference electrode with the following: NH3 buffers, sulfides, perchlorates, non-aqueous/organic solvents, and alkaline solutions stronger than 0.1M OH–.
Chemical Compatibility Caution Notice
PEEK dissolves with long exposure to concentrated acids.
Fragile Material Warning
Platinum wire is fragile. While it can be formed into a shape, repeated bending will cause the wire to break. In almost all cases, this is irreversible and cannot be repaired. Do not bend platinum wire.
Consumable U-Cups!
The PTFE U-Cup is a consumable product for the ChangeDisk RDE and RRDE tips. To ensure proper operation and longevity of the tip, Pine Research recommends replacing the U-Cup every 4-5 times you perform a ChangeDisk operation. Permanent, irreversible damage to the tip will result if the U-Cup is not regularly changed. Consider purchase a backup supply when ordering a new ChangeDisk RDE or RRDE tip.

Additional Product Details

The WaveNow Wireless Electrochemical Workstation is engineered to provide the essential hardware and software features you need at an affordable price. It supports a wide range of DC electroanalytical techniques. It offers current ranges up to ±150 mA, potential ranges up to ±8 V, wireless communication, waveform filters, and iR compensation. The WaveNow Wireless is a capable yet cost-effective workstation, which is ideal for use with stationary electrodes, RDE, and RCE. Due to its wireless capability, it is especially useful for glovebox-based electrochemistry, or other conditions where having a cable between computer and workstation is inconvenient.

AfterMath Blue - Data Acquisition, Analysis, and Organization Software

Licenses for our AfterMath® Blue software are included with the purchase of an Electrochemical Workstation. The licenses give you access to all of the DC methods that the WaveNow Wireless can perform. Pine Research does not charge extra for various categories of electrochemical techniques. If the instrument is capable of a method, you have access to it (no hidden costs). Here are some unique features of AfterMath Blue:

  • Instrument Control. When started, AfterMath automatically detects all compatible instrumentation attached to the computer and provides complete control over each instrument. It can simultaneously control multiple instruments and queue multiple experiments.
  • Flexible Plotting. AfterMath offers a powerful "drag-n-drop" feature for quickly copying and moving traces between plots, with precise control over various plot settings.
  • Scientific Units. Designed with scientific data in mind, AfterMath properly handles units, metric prefixes, and significant figures.
  • Data Archiving. A unique XML-based file format allows multiple related experiments to be stored in a single archive file, simplifying file management.
  • Tools and Transforms. Flexible tools allow precise measurement of quantities like peak height and area, with fundamental mathematical operations available on any trace.

The MSR evo Electrode Rotator is an evoLUTION of the world's most popular rotator, the . This flexible electrochemical instrument may be used with Rotating Disk Electrodes (RDE), Rotating Ring-Disk Electrodes (RRDE), and Rotating Cylinder Electrodes (RCE). The MSR evo Rotator is compatible with most international power configuration standards. The MSR evo Rotator shares many of the same technical specifications as the MSR, with a few exciting updates:

  • Rotation range increase: 0 to 11,000 RPM
  • Improved and revised control unit electronics, for improved stability.
  • Updated control unit is smaller, modern, and better laid out.
  • Added Pause/Run button to front panel (as found on the ).
  • Bright LED display on front panel replaced old LCD.
  • Continues to use the same RDE, RRDE, and RCE electrodes as the original MSR.
  • New USB port on control unit allows for future integrations and features.

The rotation rate of the electrode may be adjusted using a control knob on the front panel of the motor control unit, or alternately, the rotation rate can be controlled via an output signal from an electrochemical workstation or third-party waveform generator. The rotation rate shines brightly on the new blue LED display on the control unit. The rotation rate is adjustable over a range from 50 to 10,800 RPM and is accurate to within 1% of the reading on the display. Rotation rate may also be monitored via an output signal proportional to the rotation rate, accesible on the control unit input/output connector.

The rotation rate may be controlled and modulated by a sine wave, square wave, or other externally generated waveform. The outstanding acceleration characteristics of the motor and its control circuitry allow the rotation rate to follow the control waveform with very little error. This feature is particularly desirable for techniques such as Hydrodynamic Modulation Voltammetry (HMV).

The rotator motor position is easily raised or lowered with respect to the cell platform, making immersion or removal of the rotating electrode tip quick and easy. The enclosure base is made from chemically resistant polypropylene, and the large enclosure window provides a good view of rotating electrode during operation.

The E5TQ Series ChangeDisk Rotating Disk Electrode (RDE) tip is one of the most common RDE electrodes we offer. This tip features a 15 mm OD PEEK shroud and a removable hardware assembly, which permits the installation and removal of 5 mm OD disk inserts (Glassy Carbon disk insert included in this bundle). The tip threads into the Precision RDE/RRDE Shaft for E5, E5TQ, E6, E7, and E8 Series Tips, which is then installed into the MSR evo Electrode Rotator. Pine Research offers more electrode in more materials than anybody else. Check out all the other MSR evo compatible RDE tips we offer.

Product Specifications

The specifications of this product, and any other product that may be included in a kit or bundle, or a part that is included with this product, are listed below.
Complete RDE System Bundle: WaveNow Wireless, MSR evo, E5TQ Series RDE

Product Bundles

Product bundle
Yes
Bundle includes
Electrochemical workstation, Electrode rotator, Electrochemical cell, Reference electrode, Counter electrode, Rotating disk working electrode, Cables, Rotating Shaft, Power Cord, AfterMath Blue Software
Bundle application
General electrochemistry, Education, Photoelectrochemistry, Rotating Disk (RDE)
Bundled electrode rotator
MSR evo
Bundled electrochemical workstation
WaveNow Wireless
Precision RDE/RRDE Shaft for E5, E5TQ, E6, E7, and E8 Series Tips View Product

Electrode Shafts

Shaft length (overall)
171 mm (6.7 in)
Shaft shroud diameter
15 mm
Shaft shroud length
83 mm, 101 mm
Shaft shroud material
PEEK
Shaft rotator compatibility
MSR Rotator (AFMSRCE), MSRX Rotator (AFMSRX), MSR evo Rotator (AFMSR24)
Shaft compatible electrode tip series
E5TQ (RDE tip), E6 (RRDE tip), E5 (RDE tip), E7 (RRDE tip), E8 (RRDE tip)

Electrode Rotator

Applications
Rotating application
Rotating Disk (RDE), Rotating Ring-Disk (RRDE)
RDE/RRDE Disk Insert, 5 mm OD x 4 mm thick, Glassy Carbon (GC) View Product

Electrode Shafts

Shaft compatible electrode tip series
DTI60 (RRDE tip), E4TQ (RDE tip), E5TQ (RDE tip), E6 (RRDE tip), MTI36 (RRDE tip)

Working Electrodes

Disk Electrodes
Disk material
Glassy Carbon (GC)
Disk finish
Mirror Polish
Disk diameter
5 mm
Disk thickness
4 mm
Disk type
Insert (no electrode body)
Rotating Electrodes
Rotating electrode type
Disk Insert
Reference Electrode, Silver/Silver Chloride, Single Junction View Product
Reference size type
Standard (9.5 mm OD)
Reference electrode body diameter
9.5 mm
Reference electrode length
19 cm
Reference frit material
Ceramic
External fill solution
4 M KCl with AgCl
Refillable
yes
Typical variance
±3 - 5 mV
Typical input impedance
< 10 kΩ
Reference electrode connection style
1.6 mm OD x 8.5 mm long brass pin
Reference electrode body material
borosilicate glass

Electrochemical Properties

Reference chemistry
Ag/AgCl
Standard potential
+199 mV vs NHE
Rotation Rate Control Interface Cable, for WaveVortex 10 and MSR evo Rotators, WaveNow/WavePico Wireless View Product

Cables

Cable type
Signal, Interface
Cable terminal A type
Plug, Terminal Block, Green, 4-pin
Cable terminal B type
Plug, Terminal Block, Green, 8-pin
Cable length
3 ft
Cable color
Gray
Cable instrument compatibility
WaveNow/WavePico Wireless electrochemical workstation, MSR evo electrode rotator, WaveVortex 10 electrode rotator
WaveNow/WavePico Wireless Electrochemical Workstation Cell Cable View Product

Cables

Cable type
Workstation cell cable
Cable terminal A type
Plug, D-SUB HD 15-pin
Cable length
38 in
Cable color
Black
Cable instrument compatibility
WaveNow series electrochemical workstation, WaveNow/WavePico Wireless electrochemical workstation, WaveNow XV electrochemical workstation
Workstation Cell Cable
Number of cell cable leads
Five (5)
Cell cable lead colors
Working 1 (drive) [RED], Working 1 (sense) [ORANGE], Counter/Auxiliary [GREEN], Reference [WHITE], Instrument Chassis (ground) [GRAY]
Cell cable lead termination
Banana Plug (4 mm)
Cell cable shielded lines
Working 1 (drive), Working 1 (sense), Counter, Reference
WaveNow Series Power Supply View Product

Workstation Compatibility

Compatible electrochemical workstation
WaveNowXV (AFTP3), WaveNow (AFTP1), WaveNano (AFTP2), WaveNow Wireless (AFTP4), WavePico Wireless (AFTP5)

Electrochemical Workstations

General
Power supply input
100 to 240 VAC, 0.5 A, 50 to 60 Hz
Power supply output
5 VDC, 2.0 A Power supply (included) has a C14 type input connector
Power cord
Various international cables sold separately (C13 type)
Power Cords View Product

Power Cords

Plug style/country
United States, Canada, and Mexico, Continental Europe, United Kingdom, Denmark, Italy, Switzerland, China, Japan, Austrialia and New Zeland, South Africa, Israel, Argentina
Complete MSR Series Rotator Brush Assembly View Product

Brush Replacements

Brush housing color
Red, Blue, Yellow, Green
MSR Spring-Loaded Brush Assembly View Product
Counter Electrode Assembly, Platinum (Pt), 14/20 View Product

Counter Electrodes

Counter electrode size type
Standard (9.5 mm - 12 mm OD)
Counter body diameter
6.5 ± 0.5 mm (shroud)
Counter length
180 mm
Counter electrode material
Platinum Wire
Counter electrode connection style
1.5 mm OD x 7 mm long gold-plated pin
Counter electrode wire diameter
0.5 mm
Counter electrode wire surface area
4.7 cm²
Counter electrode platinum mass
1.3 g
Counter electrode adapter
6.4 mm to 14/20 Joint, 12 mm to 14/20 Joint
Counter electrode isolation tube frit
Ace Glass Frit D (10 – 20 µm)
Counter electrode isolation tube diameter
12 mm
Counter shroud material
Epoxy
E5TQ Series ChangeDisk Rotating Disk Electrode, PEEK View Product

Working Electrodes

Disk Electrodes
Disk electrode style
ChangeDisk
Disk diameter
5 mm
Disk type
Insert (no electrode body)
Disk series compatibility
AFED050 (5 mm OD)
Electrode Tips
Tip maximum rotation rate
3000 RPM
Tip shroud material
PEEK
Tip shroud diameter
15 mm
Tip shroud length
25.4 mm
Tip length (overall)
49 mm
Rotating Electrodes
Maximum rotation rate
3000 RPM
Shaft compatibility
RDE Shaft for ASR Rotator (AFE5A), RDE/RRDE Precision Shaft for MSR Rotator (AFE6MB), RDE/RRDE Shaft for MSR Rotator (AFE6M), RDE/RRDE Shaft for WaveVortex 10 Rotator, Non-Rotating RDE Shaft (AFE5F)
Rotating electrode type
ChangeDisk Tip
Compatible electrode rotator(s)
ASR Rotator (AFASR), MSRX Rotator (AFMSRX), MSR Rotator (AFMSRCE), MSR evo Rotator (AFMSR24), WaveVortex 10 Rotator (AF01WV10)
General
Electrode series
E5TQ
Thermal stability range
10°C - 80°C
Electrode use/application
Rotating Disk (RDE)
WaveNow Wireless Electrochemical Workstation View Product

Electrochemical Workstations

Communication
Interface
USB, Wireless
Wireless capable
Yes
General
Power input
5.0 VDC, 2 A (low voltage DC device)
Power supply input
100 to 240 VAC, 0.5 A, 50 to 60 Hz
Power supply output
5 VDC, 2.0 A Power supply (included) has a C14 type input connector
Power cord
Various international cables sold separately (C13 type)
LED indicators
Power, USB/wireless connection, status, and overload
Instrument dimensions
55 × 170 × 130 mm (2.17 × 6.69 × 5.12 in)
Workstation shipping dimensions
305 × 254 × 102 mm (12 × 10 × 4 in)
Instrument weight
0.6 kg (1.25 lb)
Workstation shipping weight
1.8 kg (4 lb)
Temperature range
10°C - 40°C
Humidity range
80% RH maximum, non-condensing
Workstation modes
Potentiostat (POT), Galvanostat (GAL), Open-Circuit Potential (OCP), Zero-Resistance Ammeter (ZRA)
Auxiliary Connections
Connector C
N/A
Trigger input
N/A
Trigger output
N/A
Potential (E1) output
N/A
Current (I1) output
N/A
Potential (E2) output
N/A
Current (I2) output
N/A
Auxiliary analog input
N/A
Auxiliary analog output
N/A
WK1 input
N/A
WK2 input
N/A
Accessories
Dummy cell
External dummy cell included
Cell cable
HD-15 male connector to multiple banana plugs via shielded coaxial cables (included)
Rotator Control Connections
Rotator connector A
N/A
Rotator connector B
4-pin connector includes chassis ground, rotator enable output signal (+15 V tolerant), analog signal ground (DC Common), and analog rotation rate control output signal
Rate control signal
±10 V
Digital enable signal
Open drain with 4.7 kΩ pull up to +4 V (TTL compatible), open drain (TTL compatible)
Electrochemical Impedance Spectroscopy (EIS)
EIS capable
No
EIS frequency range
N/A
EIS frequency resolution
N/A
EIS frequency stability
N/A
Modes
N/A
Voltage excitation setpoint
N/A
Current excitation setpoint
N/A
Frequency sweeping
N/A
EIS accuracy
N/A
Data Acquisition (for DC Experiments)
Clock resolution
500 ns (minimum time base)
Point interval
1 ms (minimum)
Synchronization
Simultaneous current and potential input
Raw point total
<10 million per experiment
Applied Potential (Potentiostatic Mode)
Potential ranges (applied)
±8 V
Potential resolution at each range (applied)
250 µV per DAC bit
DC accuracy (potential, applied)
±0.2% of setting; ±0.05% of range
DAC output (potential)
16 bits
CV sweep rate (minimum)
10 µV/s
CV sweep rate (maximum)
10 V/s
Measured Potential
Potential ranges (measured)
±8 V
Potential resolution at each range (measured)
250 µV per ADC bit
DC accuracy (potential, measured)
±0.2% of setting; ±0.05% of range
ADC output
16 bits
Filters (for DC Experiments)
12 Hz, 1 kHz
Electrometer (Reference Electrode Amplifier)
Input impedance
>10¹³ in parallel with <10 pF
Input current
6 fA leakage/bias current typical, <100 fA max at 25°C
CMRR
>73 dB, 0 - 100 Hz, >60 dB ≤1 kHz, >39 dB ≤10 kHz
Electrometer bandwidth
> 800 kHz (3 dB)
Power Amplifier (Counter Electrode Amplifier)
Output current
±150 mA (maximum)
Short circuit current limit
all ranges: 160 mA
Compliance voltage
>±11 V
Bandwidth
>30 kHz (on fastest speed setting)
Noise and ripple
undetermined
Slew rate/rise time
800 V/ms (galvanostatic mode, on fastest speed setting), 180 V/ms (on fastest speed setting)
Applied Current (Galvanostatic Mode)
Current ranges (applied)
±150 mA, ±5 mA, ±150 µA, ±5 µA, ±150 nA, ±5 nA
Current resolution at each range (applied)
4.7 µA, 157 nA, 4.7 nA, 157 pA, 4.7 pA, 157 fA
DC accuracy (current, applied)
±0.2% of setting; ±0.05% of range
DAC output (current)
16 bits
Measured Current (Potentiostatic Mode)
Current ranges (measured)
±150 mA, ±5 mA, ±150 µA, ±5 µA, ±150 nA, ±5 nA
Current resolution at each range (measured)
4.7 µA, 157 nA, 4.7 nA, 157 pA, 4.7 pA, 157 fA
Autoranging
Yes
Practical current range
1 pA to 150 mA
DC accuracy (current, measured)
±0.2% of setting plus ±0.05% of upper five current ranges; ±0.5% of 50 pA range with ±1 pA offset
DC leakage current
< 20 fA at 0 VDC, < 130 fA at 5 VDC
AC accuracy (measured)
N/A
AC leakage current
N/A
ADC input
16 bits
Filters (for DC Experiments)
12 Hz, 1 kHz
Ground Connections
DC common (signal)
The DC Common is isolated from the USB port, the instrument chassis, and earth ground. The DC Common is accessible via the Control Port on the back panel.
Chassis terminal
The instrument chassis terminal is accessible via a banana binding post (metal) on the back panel. The GRAY banana plug on the cell cable also provides a chassis connection.
Earth
No direct connection to earth ground is provided.
Electrode Connections
Reference electrode
Sense line with driven shield
Counter electrode
Drive line with grounded shield
Working electrode channels
1 Channel
Working electrode #1 (WK1)
Separate sense and drive lines, each with driven shield (current measurement via passive shunt)
Working electrode #2 (WK2)
N/A
MSR evo Electrode Rotator View Product

Electrode Rotator

Safety & Environmental
Rotator RoHS compliant
Yes
Physical
Control unit dimensions
27 × 25 × 11 cm (10.8 × 9.8 × 4.3 in)
Enclosure dimensions
48 × 40 × 54 cm (18.8 × 15.5 × 21 in)
Enclosure base and sides materials
White polypropylene (PP)
Enclosure window material
Clear polycarbonate (PC)
Center post/support rod material
303 stainless steel
Operating temperature
10 °C - 40 °C (50 °F - 104 °F)
Rotator shipping weight
27 kg (60 lb)
Rotation Rate
Rate limits
0 to 11,000 RPM
Rate accuracy
0 to 4,000 RPM: accurate to within ±2 RPM; 4,000 RPM and above: accurate to within ±1 count and ±0.1% of display reading
External rate control
Optional rate control via input signal on external I/O port; available control ratios: 1, 2, or 4 RPM/mV, jumper selectable
Rate display
4 ½ digit display indicates rotation rate (RPM)
Rate output
Voltage output accessible from back panel 8-pin connector
Start/stop (front panel)
Push-button toggle on front panel with LED indicators for “pause” and “run”
Start/stop (external)
Optional digital motor stop input signal on external I/O port, Available TTL logic: active high or active low; jumper selectable, Front panel LED indicates when external motor stop is active
Grounding
Rotator chassis terminal
Chassis connection on back panel 8-pin connector
Rotator earth ground
No direct connection available
Electrical
Electrode connections
Disk electrode: two red banana jacks on motor unit, Ring electrode: two blue banana jacks on motor unit
Rotator AC power input
100 - 240 VAC, ±10%, 50/60 Hz, 2 A
Power switch location
Front of control unit
Back panel controls
Circuit breaker reset button, 8-pin I/O connector
Front panel controls
Power switch, External/manual control switch, Run/pause button
Rotator I/O Connections
External stop signal, External voltage input (external rate control), Voltage output, Chassis ground, TTL logic (active high or active low)
Motor
Control method
Closed loop servo-system; temperature compensated tachometer mounted on motor shaft
Maximum continuous torque
30.4 mN·m
Motor power
20 W
Motor protection
2 Amp thermal-type circuit breaker current limited power supplies
Motor type
Permanent Magnet
Modulation boundaries
Modulation boundaries plot

Replacement Parts & Accessories

The products shown below are included with Complete RDE System Bundle: WaveNow Wireless, MSR evo, E5TQ Series RDE. We provide these listings so that customers may order replacement or additional components of this product. Should you want more details or wish to order an additional part, refer to the list below.

Product Documentation

Historically, much of our support content was written and published as PDF documents. We are primarily writing new support content as part of our Support Center instead; however, product user guides are still published in this format and not all historical application notes and other support documents have been migrated to the Support Center yet.

Safety Data Sheets (SDS)

If this product contains products where an SDS sheet is available, it will be displayed below.

Carbon Materials

Glassy Carbon (GC)

Electrode Polishing Materials

0.3 µm Aluminum Oxide Suspension (Alumina)
0.05 µm Aluminum Oxide Suspension (Alumina)
5 µm Aluminum Oxide Suspension (Alumina)
Grinding Disk

Elemental Metals

Platinum (Pt)

Reference Electrode Filling Solutions

4 M Potassium Chloride with Silver Chloride (KCl with AgCl)

Request a Quote for this Cart

Below is the billing data we have on file. These details will be used on your quotation, so please update them here if you require any changes. Changing any details here updates them for your account.