# | Description | Price in USD | |
---|---|---|---|
Potentiostat Bundle | |||
[NEC-WN-ONE-P] |
WaveNeuro One Basic PLUS Bundle |
||
WaveNow Plus Bundle includes the items listed below | |||
AF01FSCV1 |
WaveNeuro One FSCV Potentiostat System power cord sold separately |
||
AC01HS1 |
FSCV Headstage Amplifier |
||
RRHC0124-T |
Headstage Amplifier Cable |
||
AC01HC0315-5 |
Microelectrode-Headstage Coupler - 1.5" |
||
NI PCIe-6363 Interface Board Academic customers may wish to inquire directly with National Instruments to purchase this item. |
|||
EWCP6102 |
NI SHC68-68 EPM Interface Cable bundle includes two cables, required Academic customers may wish to inquire directly with National Instruments to purchase this item. |
||
WaveNeuro Power Cords Sold Separately | |||
Power Cords | |||
Optional Accessories | |||
RRHC0136-T |
Headstage Amplifier Cable |
||
AC01HC0325-5 |
Microelectrode-Headstage Coupler - 2.5" |
||
AC01HS2 |
FSCV Headstage Amplifier NOTE: A working electrode driven systems means the waveform is applied to the working electrode, which is then later software subtracted. Such a design is consistent with the general FSCV research community. |
The WaveNeuro One Fast Scan Cyclic Voltammetry (FSCV) Potentiostat System Basic PLUS bundle is a unique electrochemical instrument you will not find from other traditional electrochemical suppliers. We are excited to bring high quality, regularly available, and uniquely designed neuroelectrochemical research products to you. Designed by FSCV scientists for FSCV scientists, the WaveNeuro One is well-designed, of high quality construction, and supported by a company dedicated to supporting the instrument, as well as you the researcher. The WaveNeuro One seeks to fill the gap that exists for commercial fast-scan cyclic voltammetry (FSCV) systems. The PLUS bundle includes the National Instruments interface board and cable necessary to control the WaveNeuro One and collect data by PC software. The system provides you with the following:
- Includes the PCIe-6363 and interface cables
- Novel design integrates "breakout box,"potentiostat, filters, and data acquisition connectors into one box
- Intuitive and clearly-labeled connectors
- Small dimensional footprint
- Behavioral input mapping to digital and analog input/output connections included
- Designed for use with Pine Research modular headstage cable design
- Single channel FSCV for the highest affordability
The WaveNeuro One FSCV potentiostat requires a power cable. Specify the appropriate power cord style during order. Pine Research offers a wide variety of plug styles.
Stock up on Pine Headstage Cable Kits to keep you lab productive.
IMPORTANT! Pine Research does not provide software for the WaveNeuro potentiostat. Third-party software is available which allows the FSCV technique to be performed using the WaveNeuro potentiostat. Pine Research recommends that customers purchase the “HDCV” software package offered by the The University of North Carolina CRITCL Facility. The HDCV software package was developed by the original FSCV researchers, and it is described in detail in the scientific literature. Inquire directly with the CRITCL Facility to obtain an HDCV license.
The WaveNeuro One Fast-Scan Cyclic Voltammetry (FSCV) Potentiostat Basic PLUS Bundle includes the required National Instruments PCIe-6363 Data Acquisition Interface Board and two SHC68-68 EPM cables. Cusotmer is to provide a desktop PC with an open PCIe slot available on the motherboard. This bundle includes a unique electrochemical instrument you will not find from other traditional electrochemical suppliers. We are excited to bring high quality, regularly available, and uniquely designed neuroelectrochemical research products to you. Designed by FSCV scientists for FSCV scientists, the WaveNeuro One is well-designed, of high quality construction, and supported by a company dedicated to supporting the instrument, as well as you the researcher. The WaveNeuro One seeks to fill the gap that exists for commercial fast-scan cyclic voltammetry (FSCV) systems.
The WaveNeuro One Potentiostat was designed for the scientist (neuroscientist, psychologist, physician, chemist, biologist, etc.) who seeks to study the link between the brain chemistry of electroactive species (such as monoamines, catecholamines like dopamine and serotonin, oxygen, peroxide, etc.) and physiology (such as structure, function, disease, neural transmission, etc.) and behavior (such as addiction, impulsivity, decision-making, etc.). Microdialysis, still a technique used in the field, can provide high spatial resolution for detection of these chemical species but offers poor temporal resolution. FSCV, as a technique, provides both high spatial and high temporal resolution. Coupled with carbon fiber microelectrodes, FSCV provides a well-established platform for in-vivo and in-vitro experimentation.
Traditionally, the products and instrumentation required to perform FSCV have only been available through scientific connections with developing laboratories. As the technique has grown in popularity, due in part to its relative ease of use, the availability of instrumentation has not followed the same trend. We are excited to bring such FSCV instrumentation to the market, thereby providing the robust technical, service, and sales support you have come to expect in the field of research instrumentation.
The WaveNeuro One seeks to fill the gap that exists for commercial FSCV systems by providing systems with many novel features, such as:
- After official release, we will strive to have items in stock and ready to ship! Who can wait 8 weeks or more when your research productivity is on the line?
- A system that breaks from the past, with an overall updated design, including: a “breakout box” built into and included with the WaveNeuro One, intuitive and clearly-labeled connectors, in a small dimensional footprint.
- Built for flexibility – includes behavioral input mapping to digital and analog input/output connections.
- Designed with Pine Research modular headstage cable design, preventing that “pile of unknown headstage/cables” that so many labs make over time.
All specifications are subject to change without notice.
WaveNeuro One FSCV System | |
Headstage Connector |
Female DB-25 provides electrode signal lines and power to the electrochemical headstage and supports electrical stimulation (top panel) |
Behavioral Connector |
Female DB-25 provides digital input lines for external sources (top panel) |
Stimulus Connector |
Male, two-prong connector receives stimulation current from external source |
Reference Electrode |
White lead wire from the electrochemical headstage |
Working Electrode |
Yellow lead wire from the electrochemical headstage |
Working Electrode Channels |
One |
Measured Current Range |
Defined by electrochemical headstage, ±200 nA/V (5 MΩ) headstage amplifier included |
Resolution |
16-bit resolution (provided by the interface board) |
Ranges |
±3.3 V (maximum) |
Resolution |
100 µV (minimum, as defined by the interface board) |
CV Scan Rate (max) |
5,000 V/s |
Ranges |
±10.0 V (maximum, as defined by interface board) |
Point Interval |
500 ns (minimum) |
Headstage Amplifier |
200 nA/V (5 MΩ), working driven (other gains available by special order) |
Electrode Connections |
White = Reference, Yellow = Working |
Compatible DAQ Interface |
National Instruments PCIe-6363 (sold separately) |
Control Software |
Industry standard LabVIEW based software available to researchers (not provided) |
Instrument Weight |
2.0 kg (1.8 lb) |
Additional Specifications |
Document # | Title |
---|---|
WaveNeuro FSCV Potentiostat | |
DRU10120 |
WaveNeuro FSCV Potentiostat System User Guide |
HDCV Software | |
Manual |
HDCV Manual (contact Collin McKinney at University of North Carolina Chapel Hill Chemistry Department Electronics Facility) |
Manual |
HDCV Analysis Manual (contact Collin McKinney at University of North Carolina Chapel Hill Chemistry Department Electronics Facility) |
DRB10126 |
WaveNeuro Marketing Brochure |
Contact us with any questions or support requests by phone or e-mail.
Review the WaveNeuro Knowledgebase content.
Information about the National Instruments PCIe-6363 Interface Board.
Below are selected product references: