The WaveNeuro One Fast Scan Cyclic Voltammetry (FSCV) Potentiostat System Basic Bundle is a unique electrochemical instrument you will not find from other traditional electrochemical suppliers.  We are excited to bring high quality, regularly available, and uniquely designed neuroelectrochemical research products to you.  Designed by FSCV scientists for FSCV scientists, the WaveNeuro One is well-designed, of high quality construction, and supported by a company dedicated to supporting the instrument, as well as you the researcher.  The WaveNeuro seeks to fill the gap that exists for commercial fast-scan cyclic voltammetry (FSCV) systems.  The system provides you with the following:

  • Systems and accessories are in stock and ready to ship
  • Novel design integrates "breakout box", potentiostat, filters, and data acquisition connectors into one box
  • Intuitive and clearly-labeled connectors
  • Behavioral input mapping to digital and analog input/output connections included
  • Designed for use with Pine Research modular headstage cable design
  • Single channel FSCV for the highest affordability

IMPORTANT! Pine Research does not provide software for the WaveNeuro potentiostat.  Third-party software is available which allows the FSCV technique to be performed using the WaveNeuro potentiostat.  Pine Research recommends that customers purchase the "HDCV" software package offered by the The University of North Carolina CRITCL Facility.  The HDCV software package was developed by the original FSCV researchers, and it is described in detail in the scientific literature.  Inquire directly with the CRITCL Facility to obtain an HDCV license.

To view pricing or purchasing options in your country, please register or login to your account.

# Description Price in USD
Potentiostat Bundle
[NEC-WN-ONE-B]

WaveNeuro One Basic Bundle

WaveNeuro One Basic Bundle includes the items listed below
AF01FSCV1

WaveNeuro One FSCV Potentiostat System
includes power adapter

power cord sold separately

AC01HS1

FSCV Headstage Amplifier
200 nA/V, driven working

RRHC0124-T

Headstage Amplifier Cable
24", WaveNeuro/UEI potentiostat compatible, includes CP-305 stimulator connector

AC01HC0315-5

Microelectrode-Headstage Coupler - 1.5"
white reference, yellow working, pack of 5

WaveNeuro Power Cords Sold Separately
Power Cords

click here to review power cord options

Optional Accessories
RRHC0136-T

Headstage Amplifier Cable
36", WaveNeuro/UEI potentiostat compatible, includes CP-305 stimulator connector

AC01HC0325-5

Microelectrode-Headstage Coupler - 2.5"
white reference, yellow working, pack of 5

AC01HS2

FSCV Headstage Amplifier
1 MΩ; 1,000 nA/V, working electrode driven

NOTE: A working electrode driven systems means the waveform is applied to the working electrode, which is then later software subtracted. Such a design is consistent with the general FSCV research community.

The WaveNeuro One FSCV potentiostat requires a power cable.  Specify the appropriate power cord style during order.  Pine Research offers a wide variety of plug styles.

Stock up on Pine Headstage Cable Kits to keep you lab productive.

IMPORTANT! Pine Research does not provide software for the WaveNeuro potentiostat.  Third-party software is available which allows the FSCV technique to be performed using the WaveNeuro potentiostat.  Pine Research recommends that customers purchase the “HDCV” software package offered by the The University of North Carolina CRITCL Facility.  The HDCV software package was developed by the original FSCV researchers, and it is described in detail in the scientific literature.  Inquire directly with the CRITCL Facility to obtain an HDCV license.

The WaveNeuro One Fast Scan Cyclic Voltammetry (FSCV) Potentiostat Basic Bundle is a unique electrochemical instrument you will not find from other traditional electrochemical suppliers.  We are excited to bring high quality, regularly available, and uniquely designed neuroelectrochemical research products to you.  Designed by FSCV scientists for FSCV scientists, the WaveNeuro One is well-designed, of high quality construction, and supported by a company dedicated to supporting the instrument, as well as you the researcher.  The WaveNeuro One seeks to fill the gap that exists for commercial fast-scan cyclic voltammetry (FSCV) systems.

The WaveNeuro One FSCV Potentiostat Basic Bundle does not include the required PCIe-6363 National Instruments data acquisition board.  Customers must obtain this interface board separately from National Instruments directly, or consider our WaveNeuro One FSCV Plus Bundle, which includes the interface board.

The WaveNeuro One Potentiostat was designed for the scientist (neuroscientist, psychologist, physician, chemist, biologist, etc.) who seeks to study the link between the brain chemistry of electroactive species (such as monoamines, catecholamines like dopamine and serotonin, oxygen, peroxide, etc.) and physiology (such as structure, function, disease, neural transmission, etc.) and behavior (such as addiction, impulsivity, decision-making, etc.).  Microdialysis, still a technique used in the field, can provide high spatial resolution for detection of these chemical species but offers poor temporal resolution.  FSCV, as a technique, provides both high spatial and high temporal resolution.  Coupled with carbon fiber microelectrodes, FSCV provides a well-established platform for in-vivo and in-vitro experimentation.

Traditionally, the products and instrumentation required to perform FSCV have only been available through scientific connections with developing laboratories.  As the technique has grown in popularity, due in part to its relative ease of use, the availability of instrumentation has not followed the same trend.  We are excited to bring such FSCV instrumentation to the market, thereby providing the robust technical, service, and sales support you have come to expect in the field of research instrumentation.

The WaveNeuro One seeks to fill the gap that exists for commercial FSCV systems by providing systems with many novel features, such as:

  • We strive to have items in stock and ready to ship! Who can wait 8 weeks or more when your research productivity is on the line?
  • A system that breaks from the past, with an overall updated design, including: a “breakout box” built into and included with the WaveNeuro, intuitive and clearly-labeled connectors, in a small dimensional footprint.
  • Built for flexibility – includes behavioral input mapping to digital and analog input/output connections.
  • Designed with Pine Research modular headstage cable design, preventing that “pile of unknown headstage/cables” that so many labs make over time.
All specifications are subject to change without notice.
WaveNeuro One FSCV System

Headstage Connector

Female DB-25 provides electrode signal lines and power to the electrochemical headstage and supports electrical stimulation (top panel)

Behavioral Connector

Female DB-25 provides digital input lines for external sources (top panel)

Stimulus Connector

Male, two-prong connector receives stimulation current from external source

Reference Electrode

White lead wire from the electrochemical headstage

Working Electrode

Yellow lead wire from the electrochemical headstage

Working Electrode Channels

One

Measured Current Range

Defined by electrochemical headstage, ±200 nA/V (5 MΩ) headstage amplifier included

Resolution

16-bit resolution (provided by the interface board)

Ranges

±3.3 V (maximum)

Resolution

100 µV (minimum, as defined by the interface board)

CV Scan Rate (max)

5,000 V/s

Ranges

±10.0 V (maximum, as defined by interface board)

Point Interval

500 ns (minimum)

Headstage Amplifier

200 nA/V (5 MΩ), working driven (other gains available by special order)

Electrode Connections

White = Reference, Yellow = Working

Compatible DAQ Interface

National Instruments PCIe-6363 (sold separately)

Control Software

Industry standard LabVIEW based software available to researchers (not provided)

Instrument Weight

2.0 kg (1.8 lb)

Additional Specifications

click here for a complete list of specifications

Document # Title
WaveNeuro FSCV Potentiostat

DRU10120

WaveNeuro FSCV Potentiostat System User Guide
click here to download (4 MB download)

DRB10126

WaveNeuro Marketing Brochure
click here to download (1 MB download)

HDCV Software

Manual

HDCV Manual (contact Collin McKinney at University of North Carolina Chapel Hill Chemistry Department Electronics Facility)

Manual

HDCV Analysis Manual (contact Collin McKinney at University of North Carolina Chapel Hill Chemistry Department Electronics Facility)

Below are selected product references:

WaveNeuro One FSCV System [AF01FSCV1]
Questions? Find Answers.

Our knowledgebase is the central repository for written content, including help topics, theory, application notes, specifications, and software information.

Select a category below or view the Knowledgebase home page
Software

Detailed information about our Software, which includes AfterMath and retired PineChem.

Applications

Application notes discuss practical aspects of conducting specific experiments.

Theory

Fundamental electrochemical theory presented in a brief and targeted manner.

Product Specifications

Review complete product specifications and compare products within a category here.